nday
CVE-2026-44415

Siemens SIMATIC:path traversal標題由 nday 產生;CVE 紀錄未附標題。

Siemens / Industrial Edge Device Kit - arm64 V1.10、Industrial Edge Device Kit - arm64 V1.11、Industrial Edge Device Kit - arm64 V1.12、Industrial Edge Device Kit - arm64 V1.13、Industrial Edge Device Kit - arm64 V1.14、Industrial Edge Device Kit - arm64 V1.15 +92

揭露時間:。nday 尚未取得修補依據,不能據此認為沒有修補。四個 PoC 來源皆未收錄。目前未列入 CISA KEV。

tags weakness typepath traversal accessnetworkno user interaction productSiemens SIMATIC product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

path traversal
CWE-35, stated by the CNA siemens 與 NVD, republishing [email protected]
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design、Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral、Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) and 37 more
ICS / OT
affected products in the CVE record: Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design、Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral、Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) and 37 morethe product type of Siemens SIMATIC in nday's product registry
目前階段
DIS
揭露時間
CVSS
8.9 HIGH v4.0

生命週期

橫軸 UTC;點=精確到分鐘,寬條=僅日期,空心=不明或推斷。
時間不明
DIS揭露
10-13T09:18Z
PAT修補
尚無紀錄
ANA分析
尚無紀錄
POCPoC
尚無紀錄
ITW遭利用
尚無紀錄
KEVKEV
尚無紀錄

摘要

Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system or result in the deletion of data.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:P
Present: success depends on specific deployment or execution conditions, such as a race condition, a non-default setting or a position on the network path
Privileges required PR:H
High: administrative or similar privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

事件紀錄

+DIS揭露

CVE 紀錄由 siemens 發布。CVSS 8.9,屬高風險等級。

來源 cvelist · nday 於 批次匯入 · 原始
{
  "id": 424932,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2026-44415",
  "occurred_at": "2026-10-13T09:18:28.199Z",
  "observed_at": "2026-11-13T05:39:50.021609Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
      "version": "4.0",
      "base_score": 8.9,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2026-10-14T19:33:19.266421Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2026-10-13T09:18:28.199Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究員討論

近 7 天有 0 位研究員提及

名單內研究員在 X 上提及此 CVE 的貼文,照原文呈現,nday 不查核。

尚未收錄名單內研究員在 X 上提及此 CVE 的貼文。

Discussion

0 comments

No comments yet.