nday
CVE-2026-44415

Siemens SIMATIC: path traversalTitle composed by nday; the CVE record has none.

Siemens / Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15 +92

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

tags weakness typepath traversal accessnetworkno user interaction productSiemens SIMATIC product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

path traversal
CWE-35, stated by the CNA siemens and NVD, republishing [email protected]
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design, Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral, Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom), Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit, Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top), Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom), Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension, Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) and 37 more
ICS / OT
affected products in the CVE record: Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design, Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral, Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom), Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit, Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top), Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom), Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension, Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) and 37 morethe product type of Siemens SIMATIC in nday's product registry
stage
DIS
disclosed
cvss
8.9 HIGH v4.0

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
10-13T09:18Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system or result in the deletion of data.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:P
Present: success depends on specific deployment or execution conditions, such as a race condition, a non-default setting or a position on the network path
Privileges required PR:H
High: administrative or similar privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

Event log

+DISdisclosed

CVE record published by siemens. CVSS 8.9, high.

src cvelist · nday , bulk import · raw
{
  "id": 424932,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2026-44415",
  "occurred_at": "2026-10-13T09:18:28.199Z",
  "observed_at": "2026-11-13T05:39:50.021609Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
      "version": "4.0",
      "base_score": 8.9,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2026-10-14T19:33:19.266421Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2026-10-13T09:18:28.199Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.