nday
CVE-2026-44415

Siemens SIMATIC:path traversalnday が生成したタイトルです(CVE レコードにタイトルなし)。

Siemens / Industrial Edge Device Kit - arm64 V1.10、Industrial Edge Device Kit - arm64 V1.11、Industrial Edge Device Kit - arm64 V1.12、Industrial Edge Device Kit - arm64 V1.13、Industrial Edge Device Kit - arm64 V1.14、Industrial Edge Device Kit - arm64 V1.15 +92

に公開されました。nday はまだ修正の根拠を取得していません。修正がないという意味ではありません。4 つの PoC ソースのいずれにも未掲載です。CISA KEV には現時点で未掲載です。

tags weakness typepath traversal accessnetworkno user interaction productSiemens SIMATIC product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

path traversal
CWE-35, stated by the CNA siemens、NVD, republishing [email protected]
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design、Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral、Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) and 37 more
ICS / OT
affected products in the CVE record: Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design、Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral、Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) and 37 morethe product type of Siemens SIMATIC in nday's product registry
現在の段階
DIS
公開日時
CVSS 基本値
8.9 HIGH v4.0

ライフサイクル

横軸は UTC。点=分単位、幅広の帯=日付のみ、白抜き=不明または推定。
日時不明
DIS公開
10-13T09:18Z
PAT修正
記録なし
ANA解析
記録なし
POCPoC
記録なし
ITW悪用
記録なし
KEVKEV
記録なし

概要

Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system or result in the deletion of data.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:P
Present: success depends on specific deployment or execution conditions, such as a race condition, a non-default setting or a position on the network path
Privileges required PR:H
High: administrative or similar privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

イベント履歴

+DIS公開

siemens が CVE レコードを公開。CVSS 基本値 8.9(重要)。

出典 cvelist · nday が に一括取り込み · 生データ
{
  "id": 424932,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2026-44415",
  "occurred_at": "2026-10-13T09:18:28.199Z",
  "observed_at": "2026-11-13T05:39:50.021609Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
      "version": "4.0",
      "base_score": 8.9,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2026-10-14T19:33:19.266421Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2026-10-13T09:18:28.199Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究者の投稿

過去 7 日間に 0 人の研究者が言及

リストの研究者が X でこの CVE に触れた投稿です。原文のまま表示し、nday は検証していません。

リストの研究者が X でこの CVE に触れた投稿は、まだ収集していません。

Discussion

0 comments

No comments yet.