nday
CVE-2025-40805

Siemens Industrial Edge Cloud Device (IECD): broken access controlTitle composed by nday; the CVE record has none.

Siemens / Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14 +101

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

broken access control
CWE-639, stated by the CNA siemens and NVD, republishing [email protected]
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
no authentication required
PR:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC Automation Workstation 19", Siemens · SIMATIC Automation Workstation 24", Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design, Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral, Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom), Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit, Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top), Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) and 47 more
Siemens SCALANCE
affected products in the CVE record: Siemens · SCALANCE LPE9413, Siemens · SCALANCE LPE9433
router / switch
affected products in the CVE record: Siemens · SCALANCE LPE9413, Siemens · SCALANCE LPE9433the product type of Siemens SCALANCE in nday's product registry
ICS / OT
affected products in the CVE record: Siemens · SCALANCE LPE9413, Siemens · SCALANCE LPE9433, Siemens · SIMATIC Automation Workstation 19", Siemens · SIMATIC Automation Workstation 24", Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic, Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design, Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral, Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom), Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit and 49 morethe product type of Siemens SCALANCE and Siemens SIMATIC in nday's product registry
stage
DIS
disclosed
cvss
10.0 CRITICAL v4.0

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
01-13T09:44Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

Event log

+DISdisclosed

CVE record published by siemens. CVSS 10, critical.

src cvelist · nday , bulk import · raw
{
  "id": 376032,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2025-40805",
  "occurred_at": "2026-01-13T09:44:03.338Z",
  "observed_at": "2026-11-13T05:39:08.090137Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
      "version": "4.0",
      "base_score": 10,
      "base_severity": "CRITICAL"
    },
    "ssvc": {
      "timestamp": "2026-01-13T17:37:11.802050Z",
      "automatable": "yes",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2026-01-13T09:44:03.338Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.