nday
CVE-2025-40805

Siemens Industrial Edge Cloud Device (IECD):broken access controlnday が生成したタイトルです(CVE レコードにタイトルなし)。

Siemens / Industrial Edge Cloud Device (IECD)、Industrial Edge Device Kit - arm64 V1.10、Industrial Edge Device Kit - arm64 V1.11、Industrial Edge Device Kit - arm64 V1.12、Industrial Edge Device Kit - arm64 V1.13、Industrial Edge Device Kit - arm64 V1.14 +101

に公開されました。nday はまだ修正の根拠を取得していません。修正がないという意味ではありません。4 つの PoC ソースのいずれにも未掲載です。CISA KEV には現時点で未掲載です。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

broken access control
CWE-639, stated by the CNA siemens、NVD, republishing [email protected]
remote, unauthenticated
AV:N、PR:N、UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
no authentication required
PR:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC Automation Workstation 19"、Siemens · SIMATIC Automation Workstation 24"、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design、Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral、Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)、Siemens · SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) and 47 more
Siemens SCALANCE
affected products in the CVE record: Siemens · SCALANCE LPE9413、Siemens · SCALANCE LPE9433
router / switch
affected products in the CVE record: Siemens · SCALANCE LPE9413、Siemens · SCALANCE LPE9433the product type of Siemens SCALANCE in nday's product registry
ICS / OT
affected products in the CVE record: Siemens · SCALANCE LPE9413、Siemens · SCALANCE LPE9433、Siemens · SIMATIC Automation Workstation 19"、Siemens · SIMATIC Automation Workstation 24"、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic、Siemens · SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design、Siemens · SIMATIC HMI MTP1000, Unified Comfort Panel neutral、Siemens · SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)、Siemens · SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit and 49 morethe product type of Siemens SCALANCE、Siemens SIMATIC in nday's product registry
現在の段階
DIS
公開日時
CVSS 基本値
10.0 CRITICAL v4.0

ライフサイクル

横軸は UTC。点=分単位、幅広の帯=日付のみ、白抜き=不明または推定。
日時不明
DIS公開
01-13T09:44Z
PAT修正
記録なし
ANA解析
記録なし
POCPoC
記録なし
ITW悪用
記録なし
KEVKEV
記録なし

概要

Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

イベント履歴

+DIS公開

siemens が CVE レコードを公開。CVSS 基本値 10(緊急)。

出典 cvelist · nday が に一括取り込み · 生データ
{
  "id": 376032,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2025-40805",
  "occurred_at": "2026-01-13T09:44:03.338Z",
  "observed_at": "2026-11-13T05:39:08.090137Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
      "version": "4.0",
      "base_score": 10,
      "base_severity": "CRITICAL"
    },
    "ssvc": {
      "timestamp": "2026-01-13T17:37:11.802050Z",
      "automatable": "yes",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2026-01-13T09:44:03.338Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究者の投稿

過去 7 日間に 0 人の研究者が言及

リストの研究者が X でこの CVE に触れた投稿です。原文のまま表示し、nday は検証していません。

リストの研究者が X でこの CVE に触れた投稿は、まだ収集していません。

Discussion

0 comments

No comments yet.