nday
CVE-2022-0878

Novel attack against the Combined Charging System (CCS) in electric vehicles to remotely cause a denial of service

Combined Charging System / Combined Charging System, HomePlug GreenPHY

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

authentication bypass
CWE-306, stated by the CNA NCSC.ch, NVD's analysts, and NVD, republishing [email protected]
physical
AV:P in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA NCSC.ch
no authentication required
PR:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA NCSC.ch
no user interaction
UI:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA NCSC.ch
stage
DIS
disclosed
cvss
4.6 MEDIUM v3.1

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2022-04-12T12:00Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

Electric Vehicle (EV) commonly utilises the Combined Charging System (CCS) for DC rapid charging. To exchange important messages such as the State of Charge (SoC) with the Electric Vehicle Supply Equipment (EVSE) CCS uses a high-bandwidth IP link provided by the HomePlug Green PHY (HPGP) power-line communication (PLC) technology. The attack interrupts necessary control communication between the vehicle and charger, causing charging sessions to abort. The attack can be conducted wirelessly from a distance using electromagnetic interference, allowing individual vehicles or entire fleets to be disrupted simultaneously. In addition, the attack can be mounted with off-the-shelf radio hardware and minimal technical knowledge. With a power budget of 1 W, the attack is successful from around 47 m distance. The exploited behavior is a required part of the HomePlug Green PHY, DIN 70121 & ISO 15118 standards and all known implementations exhibit it. In addition to electric cars, Brokenwire affects electric ships, airplanes and heavy duty vehicles utilising these standards.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:P
Physical: needs physical access to the device
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

CVSS 3.1 vector from the CVE record, scored by the CNA NCSC.ch.

Event log

+DISdisclosed

CVE record published by NCSC.ch. CVSS 4.6, medium.

src cvelist · nday , bulk import · raw
{
  "id": 254475,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-0878",
  "occurred_at": "2022-04-12T12:00:23.108Z",
  "observed_at": "2026-11-13T05:37:31.591644Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
      "version": "3.1",
      "base_score": 4.6,
      "base_severity": "MEDIUM"
    },
    "state": "PUBLISHED",
    "date_published": "2022-04-12T12:00:23.108Z",
    "assigner_short_name": "NCSC.ch"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.