nday
CVE-2022-0878

Novel attack against the Combined Charging System (CCS) in electric vehicles to remotely cause a denial of service

Combined Charging System / Combined Charging System, HomePlug GreenPHY

CVE 공개: . nday가 아직 패치 근거를 수집하지 않았습니다. 패치가 없다는 뜻은 아닙니다. PoC 출처 4곳 모두 미등재. CISA KEV 미등재.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

authentication bypass
CWE-306, stated by the CNA NCSC.ch, NVD's analysts 및 NVD, republishing [email protected]
physical
AV:P in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA NCSC.ch
no authentication required
PR:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA NCSC.ch
no user interaction
UI:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA NCSC.ch
현재 단계
DIS
공개
CVSS
4.6 MEDIUM v3.1

생명주기

가로축 UTC. 점 = 분 단위, 넓은 막대 = 날짜만, 빈 표시 = 불명 또는 추정.
시점 알 수 없음
DIS공개
2022-04-12T12:00Z
PAT패치
아직 기록 없음
ANA분석
아직 기록 없음
POCPoC
아직 기록 없음
ITW악용
아직 기록 없음
KEVKEV
아직 기록 없음

요약

Electric Vehicle (EV) commonly utilises the Combined Charging System (CCS) for DC rapid charging. To exchange important messages such as the State of Charge (SoC) with the Electric Vehicle Supply Equipment (EVSE) CCS uses a high-bandwidth IP link provided by the HomePlug Green PHY (HPGP) power-line communication (PLC) technology. The attack interrupts necessary control communication between the vehicle and charger, causing charging sessions to abort. The attack can be conducted wirelessly from a distance using electromagnetic interference, allowing individual vehicles or entire fleets to be disrupted simultaneously. In addition, the attack can be mounted with off-the-shelf radio hardware and minimal technical knowledge. With a power budget of 1 W, the attack is successful from around 47 m distance. The exploited behavior is a required part of the HomePlug Green PHY, DIN 70121 & ISO 15118 standards and all known implementations exhibit it. In addition to electric cars, Brokenwire affects electric ships, airplanes and heavy duty vehicles utilising these standards.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:P
Physical: needs physical access to the device
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

CVSS 3.1 vector from the CVE record, scored by the CNA NCSC.ch.

이벤트 로그

+DISCVE 공개

CVE 레코드 공개(CNA: NCSC.ch). CVSS 4.6(중간).

출처 cvelist · nday 일괄 수집 · 원본
{
  "id": 254475,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-0878",
  "occurred_at": "2022-04-12T12:00:23.108Z",
  "observed_at": "2026-11-13T05:37:31.591644Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
      "version": "3.1",
      "base_score": 4.6,
      "base_severity": "MEDIUM"
    },
    "state": "PUBLISHED",
    "date_published": "2022-04-12T12:00:23.108Z",
    "assigner_short_name": "NCSC.ch"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

연구자 논의

최근 7일간 연구자 0명이 언급

목록의 연구자가 X에서 이 CVE를 언급한 게시물입니다. 원문 그대로 보여 주며 nday는 검증하지 않습니다.

명단의 연구자가 X에서 이 CVE를 언급한 게시물은 아직 수집되지 않았습니다.

Discussion

0 comments

No comments yet.