CVE-2022-30316

Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticitynday が生成したタイトルです(CVE レコードにタイトルなし)。

に公開されました。nday はまだ修正の根拠を取得していません。修正がないという意味ではありません。4 つの PoC ソースのいずれにも未掲載です。CISA KEV には現時点で未掲載です。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

physical
AV:P in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
現在の段階
DIS
公開日時
CVSS 基本値
スコアなし

ライフサイクル

横軸は UTC。点=分単位、幅広の帯=日付のみ、白抜き=不明または推定。
日時不明
DIS公開
2022-07-28T15:41Z
PAT修正
記録なし
ANA解析
記録なし
POCPoC
記録なし
ITW悪用
記録なし
KEVKEV
記録なし

概要

Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability.

Original text of the CVE record (cvelist), shown as published.

イベント履歴

+DIS公開

mitre が CVE レコードを公開。

出典 cvelist · nday が に一括取り込み · 生データ
{
  "id": 266090,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-30316",
  "occurred_at": "2022-07-28T15:41:12Z",
  "observed_at": "2026-11-13T05:37:40.655522Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2022-07-28T15:41:12.000Z",
    "assigner_short_name": "mitre"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究者の投稿

過去 7 日間に 0 人の研究者が言及

リストの研究者が X でこの CVE に触れた投稿です。原文のまま表示し、nday は検証していません。

リストの研究者が X でこの CVE に触れた投稿は、まだ収集していません。

Discussion

0 comments

No comments yet.