nday
CVE-2024-49849

Siemens SIMATIC:deserialization of untrusted data標題由 nday 產生;CVE 紀錄未附標題。

Siemens / SIMATIC S7-PLCSIM V16、SIMATIC S7-PLCSIM V17、SIMATIC STEP 7 Safety V16、SIMATIC STEP 7 Safety V17、SIMATIC STEP 7 Safety V18、SIMATIC STEP 7 Safety V19 +33

揭露時間:。nday 尚未取得修補依據,不能據此認為沒有修補。四個 PoC 來源皆未收錄。目前未列入 CISA KEV。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

deserialization of untrusted data
CWE-502, stated by the CNA siemens 與 NVD, republishing [email protected]
local
AV:L in CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
no authentication required
PR:N in CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC S7-PLCSIM V16、Siemens · SIMATIC S7-PLCSIM V17、Siemens · SIMATIC STEP 7 Safety V16、Siemens · SIMATIC STEP 7 Safety V17、Siemens · SIMATIC STEP 7 Safety V18、Siemens · SIMATIC STEP 7 Safety V19、Siemens · SIMATIC STEP 7 V16、Siemens · SIMATIC STEP 7 V17、Siemens · SIMATIC STEP 7 V18、Siemens · SIMATIC STEP 7 V19 and 8 more
ICS / OT
affected products in the CVE record: Siemens · SIMATIC S7-PLCSIM V16、Siemens · SIMATIC S7-PLCSIM V17、Siemens · SIMATIC STEP 7 Safety V16、Siemens · SIMATIC STEP 7 Safety V17、Siemens · SIMATIC STEP 7 Safety V18、Siemens · SIMATIC STEP 7 Safety V19、Siemens · SIMATIC STEP 7 V16、Siemens · SIMATIC STEP 7 V17、Siemens · SIMATIC STEP 7 V18、Siemens · SIMATIC STEP 7 V19 and 8 morethe product type of Siemens SIMATIC in nday's product registry
目前階段
DIS
揭露時間
CVSS
8.4 HIGH v4.0

生命週期

橫軸 UTC;點=精確到分鐘,寬條=僅日期,空心=不明或推斷。
時間不明
DIS揭露
2024-12-10T13:53Z
PAT修補
尚無紀錄
ANA分析
尚無紀錄
POCPoC
尚無紀錄
ITW遭利用
尚無紀錄
KEVKEV
尚無紀錄

摘要

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:L
Local: needs a local or SSH session, or a user tricked into acting on the machine
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:A
Active: a user must deliberately do something specific, such as install or run a file or dismiss a warning

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

事件紀錄

+DIS揭露

CVE 紀錄由 siemens 發布。CVSS 8.4,屬高風險等級。

來源 cvelist · nday 於 批次匯入 · 原始
{
  "id": 2732,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2024-49849",
  "occurred_at": "2024-12-10T13:53:56.043Z",
  "observed_at": "2026-11-12T14:10:31.286634Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 8.4,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2024-12-11T17:14:22.243197Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2024-12-10T13:53:56.043Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究員討論

近 7 天有 0 位研究員提及

名單內研究員在 X 上提及此 CVE 的貼文,照原文呈現,nday 不查核。

尚未收錄名單內研究員在 X 上提及此 CVE 的貼文。

Discussion

0 comments

No comments yet.