nday
CVE-2024-43655

Any authenticated users can execute OS commands as root using the <redacted>.sh CGI script.

Iocharger / Iocharger firmware for AC models

揭露時間:。nday 尚未取得修補依據,不能據此認為沒有修補。四個 PoC 來源皆未收錄。目前未列入 CISA KEV。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

command injection
CWE-78, stated by the CNA DIVD 與 NVD, republishing [email protected]
improper privilege management
CWE-250, stated by the CNA DIVD 與 NVD, republishing [email protected]
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y (CVSS 4.0) from the CNA DIVD
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y (CVSS 4.0) from the CNA DIVD
目前階段
DIS
揭露時間
CVSS
9.3 CRITICAL v4.0

生命週期

橫軸 UTC;點=精確到分鐘,寬條=僅日期,空心=不明或推斷。
時間不明
DIS揭露
2025-01-09T07:56Z
PAT修補
尚無紀錄
ANA分析
尚無紀錄
POCPoC
尚無紀錄
ITW遭利用
尚無紀錄
KEVKEV
尚無紀錄

摘要

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root

This issue affects Iocharger firmware for AC model chargers before version 24120701.

Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.

Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.

CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:L
Low: ordinary user privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y

CVSS 4.0 vector from the CVE record, scored by the CNA DIVD.

事件紀錄

+DIS揭露

CVE 紀錄由 DIVD 發布。CVSS 9.3,屬重大等級。

來源 cvelist · nday 於 批次匯入 · 原始
{
  "id": 339588,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2024-43655",
  "occurred_at": "2025-01-09T07:56:45.279Z",
  "observed_at": "2026-11-13T05:38:38.958665Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
      "version": "4.0",
      "base_score": 9.3,
      "base_severity": "CRITICAL"
    },
    "ssvc": {
      "timestamp": "2025-01-09T15:11:43.639526Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2025-01-09T07:56:45.279Z",
    "assigner_short_name": "DIVD"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究員討論

近 7 天有 0 位研究員提及

名單內研究員在 X 上提及此 CVE 的貼文,照原文呈現,nday 不查核。

尚未收錄名單內研究員在 X 上提及此 CVE 的貼文。

Discussion

0 comments

No comments yet.