nday
CVE-2023-23588

Siemens SIMATIC:cryptographic failure標題由 nday 產生;CVE 紀錄未附標題。

Siemens / SIMATIC IPC1047、SIMATIC IPC1047E、SIMATIC IPC647D、SIMATIC IPC647E、SIMATIC IPC847D、SIMATIC IPC847E

揭露時間:。nday 尚未取得修補依據,不能據此認為沒有修補。四個 PoC 來源皆未收錄。目前未列入 CISA KEV。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

cryptographic failure
CWE-295, stated by NVD's analysts
information disclosure
CWE-200, stated by the CNA siemens 與 NVD, republishing [email protected]
local
AV:L in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no authentication required
PR:N in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no user interaction
UI:N in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC IPC1047、Siemens · SIMATIC IPC1047E、Siemens · SIMATIC IPC647D、Siemens · SIMATIC IPC647E、Siemens · SIMATIC IPC847D、Siemens · SIMATIC IPC847ECPE names NVD's analysts give as vulnerable: o:siemens:simatic_ipc1047_firmware、o:siemens:simatic_ipc647d_firmware、o:siemens:simatic_ipc847d_firmware
ICS / OT
affected products in the CVE record: Siemens · SIMATIC IPC1047、Siemens · SIMATIC IPC1047E、Siemens · SIMATIC IPC647D、Siemens · SIMATIC IPC647E、Siemens · SIMATIC IPC847D、Siemens · SIMATIC IPC847ECPE names NVD's analysts give as vulnerable: o:siemens:simatic_ipc1047_firmware、o:siemens:simatic_ipc647d_firmware、o:siemens:simatic_ipc847d_firmwarethe product type of Siemens SIMATIC in nday's product registry
目前階段
DIS
揭露時間
CVSS
6.2 MEDIUM v3.1

生命週期

橫軸 UTC;點=精確到分鐘,寬條=僅日期,空心=不明或推斷。
時間不明
DIS揭露
2023-04-11T09:03Z
PAT修補
尚無紀錄
ANA分析
尚無紀錄
POCPoC
尚無紀錄
ITW遭利用
尚無紀錄
KEVKEV
尚無紀錄

摘要

A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:L
Local: needs a local or SSH session, or a user tricked into acting on the machine
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C

CVSS 3.1 vector from the CVE record, scored by the CNA siemens.

事件紀錄

+DIS揭露

CVE 紀錄由 siemens 發布。CVSS 6.2,屬中風險等級。

來源 cvelist · nday 於 批次匯入 · 原始
{
  "id": 289457,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2023-23588",
  "occurred_at": "2023-04-11T09:03:01.13Z",
  "observed_at": "2026-11-13T05:37:59.296386Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
      "version": "3.1",
      "base_score": 6.2,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2024-10-15T17:09:07.958283Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2023-04-11T09:03:01.130Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究員討論

近 7 天有 0 位研究員提及

名單內研究員在 X 上提及此 CVE 的貼文,照原文呈現,nday 不查核。

尚未收錄名單內研究員在 X 上提及此 CVE 的貼文。

Discussion

0 comments

No comments yet.