Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric…標題由 nday 產生;CVE 紀錄未附標題。

Mitsubishi Electric / GENESIS64 · Mitsubishi Electric Iconics Digital Solutions / GENESIS64 · Mitsubishi Electric / ICONICS Suite · Mitsubishi Electric Iconics Digital Solutions / ICONICS Suite · Mitsubishi Electric / MC Works64

揭露時間:。nday 尚未取得修補依據,不能據此認為沒有修補。四個 PoC 來源皆未收錄。目前未列入 CISA KEV。

tags accesslocalno authentication required product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

local
AV:L in CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H (CVSS 3.1) from the CNA Mitsubishi
no authentication required
PR:N in CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H (CVSS 3.1) from the CNA Mitsubishi
ICS / OT
affected products in the CVE record: Mitsubishi Electric · GENESIS64、Mitsubishi Electric · ICONICS Suite、Mitsubishi Electric · MC Works64、Mitsubishi Electric Iconics Digital Solutions · GENESIS64、Mitsubishi Electric Iconics Digital Solutions · ICONICS SuiteCPE names NVD's analysts give as vulnerable: a:iconics:genesis64nday's type rule mitsubishi:automation、vendor:iconics
目前階段
DIS
揭露時間
CVSS
7.8 HIGH v3.1

生命週期

橫軸 UTC;點=精確到分鐘,寬條=僅日期,空心=不明或推斷。
時間不明
DIS揭露
2022-07-20T16:53Z
PAT修補
尚無紀錄
ANA分析
尚無紀錄
POCPoC
尚無紀錄
ITW遭利用
尚無紀錄
KEVKEV
尚無紀錄

摘要

Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:L
Local: needs a local or SSH session, or a user tricked into acting on the machine
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:R
Required: a user must do something, such as open a file or click a link

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

CVSS 3.1 vector from the CVE record, scored by the CNA Mitsubishi.

事件紀錄

+DIS揭露

CVE 紀錄由 Mitsubishi 發布。CVSS 7.8,屬高風險等級。

來源 cvelist · nday 於 批次匯入 · 原始
{
  "id": 268330,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-33317",
  "occurred_at": "2022-07-20T16:53:59Z",
  "observed_at": "2026-11-13T05:37:42.261111Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
      "version": "3.1",
      "base_score": 7.8,
      "base_severity": "HIGH"
    },
    "state": "PUBLISHED",
    "date_published": "2022-07-20T16:53:59.000Z",
    "assigner_short_name": "Mitsubishi"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究員討論

近 7 天有 0 位研究員提及

名單內研究員在 X 上提及此 CVE 的貼文,照原文呈現,nday 不查核。

尚未收錄名單內研究員在 X 上提及此 CVE 的貼文。

Discussion

0 comments

No comments yet.