nday
CVE-2020-11639

Insufficient access control on Inter process communication,

ABB / Advant MOD 300 AdvaBuild

揭露時間:。nday 尚未取得修補依據,不能據此認為沒有修補。四個 PoC 來源皆未收錄。目前未列入 CISA KEV。

tags accesslocalno user interaction product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

local
AV:L in CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from the CNA ABB
no user interaction
UI:N in CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from the CNA ABB
ICS / OT
affected products in the CVE record: ABB · Advant MOD 300 AdvaBuildCPE names NVD's analysts give as vulnerable: a:abb:advabuildnday's type rule vendor:abb
目前階段
DIS
揭露時間
CVSS
7.8 HIGH v3.1

生命週期

橫軸 UTC;點=精確到分鐘,寬條=僅日期,空心=不明或推斷。
時間不明
DIS揭露
2024-07-23T17:26Z
PAT修補
尚無紀錄
ANA分析
尚無紀錄
POCPoC
尚無紀錄
ITW遭利用
尚無紀錄
KEVKEV
尚無紀錄

摘要

An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information.

This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.

For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:L
Local: needs a local or SSH session, or a user tricked into acting on the machine
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:L
Low: ordinary user privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS 3.1 vector from the CVE record, scored by the CNA ABB.

事件紀錄

+DIS揭露

CVE 紀錄由 ABB 發布。CVSS 7.8,屬高風險等級。

來源 cvelist · nday 於 批次匯入 · 原始
{
  "id": 220526,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2020-11639",
  "occurred_at": "2024-07-23T17:26:55.489Z",
  "observed_at": "2026-11-13T05:37:08.736829Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
      "version": "3.1",
      "base_score": 7.8,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2024-07-23T19:03:27.748360Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2024-07-23T17:26:55.489Z",
    "assigner_short_name": "ABB"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究員討論

近 7 天有 0 位研究員提及

名單內研究員在 X 上提及此 CVE 的貼文,照原文呈現,nday 不查核。

尚未收錄名單內研究員在 X 上提及此 CVE 的貼文。

Discussion

0 comments

No comments yet.