nday
CVE-2019-10943

A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET…標題由 nday 產生;CVE 紀錄未附標題。

Siemens / SIMATIC Drive Controller family、SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)、SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)、SIMATIC S7-1200 CPU family (incl. SIPLUS variants)、SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)、SIMATIC S7-1500 Software Controller +1

揭露時間:。nday 尚未取得修補依據,不能據此認為沒有修補。四個 PoC 來源皆未收錄。目前未列入 CISA KEV。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

remote, unauthenticated
AV:N、PR:N、UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC Drive Controller family、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)、Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)、Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)、Siemens · SIMATIC S7-1500 Software Controller、Siemens · SIMATIC S7-PLCSIM AdvancedCPE names NVD's analysts give as vulnerable: o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware、o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware、o:siemens:simatic_s7-1200_cpu_1211c_firmware、o:siemens:simatic_s7-1200_cpu_1212c_firmware、o:siemens:simatic_s7-1200_cpu_1214c_firmware、o:siemens:simatic_s7-1200_cpu_1215c_firmware、o:siemens:simatic_s7-1200_cpu_1217c_firmware、o:siemens:simatic_s7-1500_cpu_1511c_firmware、o:siemens:simatic_s7-1500_cpu_1512c_firmware、o:siemens:simatic_s7-1500_cpu_1518_firmware and 2 more
ICS / OT
affected products in the CVE record: Siemens · SIMATIC Drive Controller family、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)、Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)、Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)、Siemens · SIMATIC S7-1500 Software Controller、Siemens · SIMATIC S7-PLCSIM AdvancedCPE names NVD's analysts give as vulnerable: o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware、o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware、o:siemens:simatic_s7-1200_cpu_1211c_firmware、o:siemens:simatic_s7-1200_cpu_1212c_firmware、o:siemens:simatic_s7-1200_cpu_1214c_firmware、o:siemens:simatic_s7-1200_cpu_1215c_firmware、o:siemens:simatic_s7-1200_cpu_1217c_firmware、o:siemens:simatic_s7-1500_cpu_1511c_firmware、o:siemens:simatic_s7-1500_cpu_1512c_firmware、o:siemens:simatic_s7-1500_cpu_1518_firmware and 2 morethe product type of Siemens SIMATIC in nday's product registry
目前階段
DIS
揭露時間
CVSS
暫無評分

生命週期

橫軸 UTC;點=精確到分鐘,寬條=僅日期,空心=不明或推斷。
時間不明
DIS揭露
2019-08-13T18:55Z
PAT修補
尚無紀錄
ANA分析
尚無紀錄
POCPoC
尚無紀錄
ITW遭利用
尚無紀錄
KEVKEV
尚無紀錄

摘要

A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.

Original text of the CVE record (cvelist), shown as published.

事件紀錄

+DIS揭露

CVE 紀錄由 siemens 發布。

來源 cvelist · nday 於 批次匯入 · 原始
{
  "id": 202485,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2019-10943",
  "occurred_at": "2019-08-13T18:55:57Z",
  "observed_at": "2026-11-13T05:36:55.820159Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2019-08-13T18:55:57.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究員討論

近 7 天有 0 位研究員提及

名單內研究員在 X 上提及此 CVE 的貼文,照原文呈現,nday 不查核。

尚未收錄名單內研究員在 X 上提及此 CVE 的貼文。

Discussion

0 comments

No comments yet.