nday
CVE-2024-51977

Unauthenticated leak of sensitive information affecting multiple models from Brother Industries, Ltd., FUJIFILM Business Innovation, Ricoh, Toshiba Tec, and Konica Minolta, Inc.

Brother Industries, Ltd / HL-L8260CDN、DCP-J928N-W/B、DCP-J987N-W/B、DCP-T510W(China)、DCP-T710W(China)、MFC-J1800DW (Europe) +445

披露于 。本站尚未获取修复依据,不能据此认为没有补丁。PoC 来源中 metasploit、nuclei 已收录(2/4)。尚未列入 CISA KEV。

这些标签的依据

这些标签由 nday 按固定规则从下列事实自动推导,不是 NVD、编号分配方或其他来源给出的。全部标签和规则见 ~/tags。

information disclosure
CWE-538(来源:编号分配方 rapid7、NVD(转录自 [email protected]))
远程未授权
编号分配方 rapid7 给出的 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N(CVSS 3.1)中的 AV:N、PR:N、UI:N
网络
编号分配方 rapid7 给出的 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N(CVSS 3.1)中的 AV:N
无需认证
编号分配方 rapid7 给出的 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N(CVSS 3.1)中的 PR:N
无需用户交互
编号分配方 rapid7 给出的 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N(CVSS 3.1)中的 UI:N
Metasploit
Metasploit 模块 auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978
nuclei
nuclei 模板 CVE-2024-51977
打印机
CVE 记录列出的受影响产品:Konica Minolta, Inc. · bizhub 3000MF、Konica Minolta, Inc. · bizhub 3080MF、Konica Minolta, Inc. · bizhub 4000i、Konica Minolta, Inc. · bizhub 4020i、Konica Minolta, Inc. · bizhub 5000i、Konica Minolta, Inc. · bizhub 5020inday 的类型规则 words:printer
当前阶段
POC
披露
CVSS
5.3 MEDIUM v3.1

生命周期

横轴 UTC;点=精确到分钟,宽条=仅日期,空心=未知或推定。
时间未知
DIS披露
2025-06-25T07:15Z
PAT补丁
尚无记录
ANA分析
尚无记录
POCPoC
metasploit、nuclei
ITW在野
尚无记录
KEVKEV
尚无记录

摘要

An unauthenticated attacker who can access either the HTTP service (TCP port 80), the HTTPS service (TCP port 443), or the IPP service (TCP port 631), can leak several pieces of sensitive information from a vulnerable device. The URI path /etc/mnt_info.csv can be accessed via a GET request and no authentication is required. The returned result is a comma separated value (CSV) table of information. The leaked information includes the device’s model, firmware version, IP address, and serial number.

以上是 CVE 记录(cvelist)中的原文,未经改写。

利用条件

按 CVSS 向量说明攻击需要的条件。
攻击途径 AV:N
网络:攻击者只要能通过网络访问到目标即可
攻击复杂度 AC:L
低:不依赖特殊条件,攻击者可预期重复成功
所需权限 PR:N
无:不需要账号或授权
用户交互 UI:N
无:除攻击者外不需要任何人配合

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

CVSS 3.1 向量,来自 CVE 记录,由 CNA rapid7 评定。

事件记录

+DIS披露

CVE 记录发布,编号分配方是 rapid7。CVSS 5.3,中危。CISA 的 SSVC 评估中利用状态为 poc。

来源 cvelist · 本站 批量导入 · 原始记录
{
  "id": 60116,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2024-51977",
  "occurred_at": "2025-06-25T07:15:16.8Z",
  "observed_at": "2026-11-12T17:00:49.411818Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
      "version": "3.1",
      "base_score": 5.3,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2025-06-26T14:33:48.841878Z",
      "automatable": "yes",
      "exploitation": "poc",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2025-06-25T07:15:16.800Z",
    "assigner_short_name": "rapid7"
  }
}
时间未知来源未给出时间
+POC公开 PoC

Metasploit 收录模块 auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978(Multiple Brother devices authentication bypass via default administrator password generation)。来源没有给出模块的发布时间。

来源 metasploit auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978 · 本站 批量导入 · 原始记录
{
  "id": 49648,
  "type": "poc_published",
  "source": "metasploit",
  "url": "https://github.com/rapid7/metasploit-framework/blob/master/modules/auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978.rb",
  "occurred_at": null,
  "observed_at": "2026-11-12T15:24:51.477477Z",
  "is_backfill": true,
  "dedupe_key": "auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978",
  "detail": {
    "url": "https://github.com/rapid7/metasploit-framework/blob/master/modules/auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978.rb",
    "kind": "msf_module",
    "path": "/modules/auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978.rb",
    "rank": 300,
    "check": false,
    "title": "Multiple Brother devices authentication bypass via default administrator password generation",
    "cve_ids": [
      "CVE-2024-51977",
      "CVE-2024-51978"
    ],
    "fullname": "auxiliary/admin/misc/brother_default_admin_auth_bypass_cve_2024_51978",
    "rank_name": "normal",
    "confidence": "curated",
    "module_type": "auxiliary",
    "module_last_modified": "2025-07-09 14:59:54 +0000",
    "vuln_disclosure_date": "2025-06-25"
  }
}
时间未知来源未给出时间
+POC公开 PoC

Nuclei 收录检测模板 CVE-2024-51977(Brother MFC-L9570CDW - Information Disclosure)。来源没有给出模板的发布时间。

来源 nuclei · 本站 批量导入 · 原始记录
{
  "id": 56436,
  "type": "poc_published",
  "source": "nuclei",
  "url": "https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2024/CVE-2024-51977.yaml",
  "occurred_at": null,
  "observed_at": "2026-11-12T15:24:53.738369Z",
  "is_backfill": true,
  "dedupe_key": "CVE-2024-51977",
  "detail": {
    "url": "https://github.com/projectdiscovery/nuclei-templates/blob/main/http/cves/2024/CVE-2024-51977.yaml",
    "kind": "detection_template",
    "title": "Brother MFC-L9570CDW - Information Disclosure",
    "severity": "medium",
    "confidence": "curated",
    "cvss_score": "N/A",
    "template_id": "CVE-2024-51977",
    "template_path": "http/cves/2024/CVE-2024-51977.yaml"
  }
}

纠错

报告错误或缺失

页面有误或缺失?告诉编辑;采纳后在本页修订记录公开说明,上游数据不会被改动。

研究员讨论

近 7 天有 0 位研究员提到

研究员在 X 上提到此 CVE 的帖子,原文照录,nday 不核实。

尚未采集到名单内研究员在 X 上提到此 CVE 的帖子。

讨论

0 条评论

还没有评论。