# 摘要
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
以上是 CVE 记录(cvelist)中的原文,未经改写。
# 利用条件
按 CVSS 向量说明攻击需要的条件。
- 攻击途径
AV:N - 网络:攻击者只要能通过网络访问到目标即可
- 攻击复杂度
AC:L - 低:不依赖特殊条件,攻击者可预期重复成功
- 所需权限
PR:N - 无:不需要账号或授权
- 用户交互
UI:N - 无:除攻击者外不需要任何人配合
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 3.1 向量,来自 CVE 记录,由 ADP CISA-ADP 补充。
# 事件记录
+DIS披露
CVE 记录发布,编号分配方是 siemens。CVSS 9.8,严重。
来源 cvelist · 本站 批量导入 · 原始记录
{
"id": 240040,
"type": "disclosed",
"source": "cvelist",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27384",
"occurred_at": "2021-05-12T13:18:22Z",
"observed_at": "2026-11-13T05:37:21.680629Z",
"is_backfill": true,
"dedupe_key": "",
"detail": {
"cvss": {
"source": "adp:CISA-ADP",
"vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1",
"base_score": 9.8,
"base_severity": "CRITICAL"
},
"ssvc": {
"timestamp": "2026-06-02T19:09:38.723689Z",
"automatable": "yes",
"exploitation": "none",
"technical_impact": "total"
},
"state": "PUBLISHED",
"date_published": "2021-05-12T13:18:22.000Z",
"assigner_short_name": "siemens"
}
}
# 纠错
报告错误或缺失
页面有误或缺失?告诉编辑;采纳后在本页修订记录公开说明,上游数据不会被改动。
无法确认登录状态,请刷新页面后再提交纠错。
请先在账号页设置公开用户名:被采纳的纠错会以它署名。
设置用户名
你的账号已被封禁,暂时不能提交纠错。
# 研究员讨论
近 7 天有 0 位研究员提到
研究员在 X 上提到此 CVE 的帖子,原文照录,nday 不核实。
尚未采集到名单内研究员在 X 上提到此 CVE 的帖子。
# 讨论
0 条评论
无法确认你的登录状态,刷新页面后再发表评论。
评论以 @用户名 署名。请先在账号页设置用户名。
前往账号页
你的账号已被封禁,不能发表、回复、编辑或举报评论;仍可删除自己的评论。
格式
↵↵- 空一行:新段落
↵- 换行:原样保留
*…*- 强调(斜体)
**…**- 加粗
`…`- 行内代码
```- 单独一行:开始和结束代码块
> …- 引用
- …- 列表
1. …- 编号列表
[…](https://…)- 链接(仅限 http 和 https)
https://…- 裸地址:自动成为链接
CVE-2026-1234- 链接到本站该漏洞页
\*- 按原样显示该字符
标题、图片、表格、嵌套列表和 HTML 都按纯文本显示。
新账号发的链接显示为纯文本;CVE 编号始终可点击。