Siemens / SIMATIC Drive Controller family、SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)、SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)、SIMATIC S7-1200 CPU family (incl. SIPLUS variants)、SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)、SIMATIC S7-1500 Software Controller +4
CVE 记录列出的受影响产品:Siemens · SIMATIC Drive Controller family、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)、Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)、Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)、Siemens · SIMATIC S7-1500 Software Controller、Siemens · SIMATIC S7-PLCSIM AdvancedNVD 分析人员标为易受攻击的 CPE 名称:o:siemens:simatic_driver_controller_firmware、a:siemens:simatic_s7-1500__software_controller、a:siemens:simatic_s7-plcsim_advanced
CVE 记录列出的受影响产品:Siemens · SIMATIC Drive Controller family、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)、Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)、Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)、Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)、Siemens · SIMATIC S7-1500 Software Controller、Siemens · SIMATIC S7-PLCSIM AdvancedNVD 分析人员标为易受攻击的 CPE 名称:o:siemens:simatic_driver_controller_firmware、a:siemens:simatic_s7-1500__software_controller、a:siemens:simatic_s7-plcsim_advancednday 产品登记表中 Siemens SIMATIC 的产品类型
当前阶段
DIS
披露
CVSS
9.8 CRITICAL v3.1
# 生命周期
横轴 UTC;点=精确到分钟,宽条=仅日期,空心=未知或推定。
时间未知
DIS披露
PAT补丁
尚无记录
ANA分析
尚无记录
POCPoC
尚无记录
ITW在野
尚无记录
KEVKEV
尚无记录
# 摘要
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.