nday
CVE-2012-6440

Rockwell Automation ControlLogix PLC Improper Input Validation

Rockwell Automation / 1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules、CompactLogix L32E and L35E controllers、1788-ENBT FLEXLogix adapter、1794-AENTR FLEX I/O EtherNet/IP adapter、ControlLogix, CompactLogix, GuardLogix, and SoftLogix、CompactLogix and SoftLogix controllers +2

披露于 。本站尚未获取修复依据,不能据此认为没有补丁。四个 PoC 来源都还没有收录。尚未列入 CISA KEV。

这些标签的依据

这些标签由 nday 按固定规则从下列事实自动推导,不是 NVD、编号分配方或其他来源给出的。全部标签和规则见 ~/tags。

authentication bypass
CWE-287(来源:编号分配方 icscert、NVD 分析人员、NVD(转录自 [email protected]))
远程未授权
ADP CISA-ADP 给出的 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N(CVSS 3.1)中的 AV:N、PR:N、UI:N
网络
ADP CISA-ADP 给出的 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N(CVSS 3.1)中的 AV:N
无需认证
ADP CISA-ADP 给出的 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N(CVSS 3.1)中的 PR:N
无需用户交互
ADP CISA-ADP 给出的 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N(CVSS 3.1)中的 UI:N
工控 ICS/OT
CVE 记录列出的受影响产品:Rockwell Automation · 1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules、Rockwell Automation · 1788-ENBT FLEXLogix adapter、Rockwell Automation · 1794-AENTR FLEX I/O EtherNet/IP adapter、Rockwell Automation · CompactLogix L32E and L35E controllers、Rockwell Automation · CompactLogix and SoftLogix controllers、Rockwell Automation · ControlLogix and GuardLogix controllers、Rockwell Automation · ControlLogix, CompactLogix, GuardLogix, and SoftLogix、Rockwell Automation · MicroLogixNVD 分析人员标为易受攻击的 CPE 名称:h:rockwellautomation:1756-enbt、h:rockwellautomation:1756-eweb、h:rockwellautomation:1768-enbt、h:rockwellautomation:1768-eweb、h:rockwellautomation:1794-aentr_flex_i/o_ethernet/ip_adapter、h:rockwellautomation:compactlogix、h:rockwellautomation:compactlogix_controllers、h:rockwellautomation:compactlogix_l32e_controller、h:rockwellautomation:compactlogix_l35e_controller、h:rockwellautomation:controllogix,另有 7 个nday 的类型规则 vendor:rockwell
当前阶段
DIS
披露
CVSS
9.3 v2.0

生命周期

横轴 UTC;点=精确到分钟,宽条=仅日期,空心=未知或推定。
时间未知
DIS披露
2013-01-24T21:00Z
PAT补丁
尚无记录
ANA分析
尚无记录
POCPoC
尚无记录
ITW在野
尚无记录
KEVKEV
尚无记录

摘要

The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information.

Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

以上是 CVE 记录(cvelist)中的原文,未经改写。

利用条件

按 CVSS 向量说明攻击需要的条件。
攻击途径 AV:N
网络:攻击者只要能通过网络访问到目标即可
攻击复杂度 AC:M
中:需要一定条件,例如非默认配置或只针对特定范围的目标
身份认证 Au:N
无:不需要认证

AV:N/AC:M/Au:N/C:C/I:C/A:C

CVSS 2.0 向量,来自 CVE 记录,由 CNA icscert 评定。

事件记录

+DIS披露

CVE 记录发布,编号分配方是 icscert。CVSS 9.3。

来源 cvelist · 本站 批量导入 · 原始记录
{
  "id": 129373,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2012-6440",
  "occurred_at": "2013-01-24T21:00:00Z",
  "observed_at": "2026-11-13T05:36:09.95838Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
      "version": "2.0",
      "base_score": 9.3,
      "base_severity": null
    },
    "ssvc": {
      "timestamp": "2026-06-03T13:34:42.563148Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2013-01-24T21:00:00.000Z",
    "assigner_short_name": "icscert"
  }
}

纠错

报告错误或缺失

页面有误或缺失?告诉编辑;采纳后在本页修订记录公开说明,上游数据不会被改动。

研究员讨论

近 7 天有 0 位研究员提到

研究员在 X 上提到此 CVE 的帖子,原文照录,nday 不核实。

尚未采集到名单内研究员在 X 上提到此 CVE 的帖子。

讨论

0 条评论

还没有评论。