CVE-2025-50123

Schneider Electric EcoStruxure™ IT Data Center Expert: code injectionTitle composed by nday; the CVE record has none.

Schneider Electric / EcoStruxure™ IT Data Center Expert

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

tags weakness typecode injection accessphysicalno user interaction product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

code injection
CWE-94, stated by the CNA schneider and NVD, republishing [email protected]
physical
AV:P in CVSS:4.0/AV:P/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H (CVSS 4.0) from the CNA schneider
no user interaction
UI:N in CVSS:4.0/AV:P/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H (CVSS 4.0) from the CNA schneider
ICS / OT
affected products in the CVE record: Schneider Electric · EcoStruxure™ IT Data Center Expertnday's type rule vendor:schneider-electric
stage
DIS
disclosed
cvss
7.2 HIGH v4.0

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2025-07-11T10:08Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

A

CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote command execution by a privileged account when the server is accessed via a console and through exploitation of the hostname input.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:P
Physical: needs physical access to the device
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:P
Present: success depends on specific deployment or execution conditions, such as a race condition, a non-default setting or a position on the network path
Privileges required PR:H
High: administrative or similar privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:P/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H

CVSS 4.0 vector from the CVE record, scored by the CNA schneider.

Event log

+DISdisclosed

CVE record published by schneider. CVSS 7.2, high.

src cvelist · nday , bulk import · raw
{
  "id": 380849,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2025-50123",
  "occurred_at": "2025-07-11T10:08:36.56Z",
  "observed_at": "2026-11-13T05:39:12.854975Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:P/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
      "version": "4.0",
      "base_score": 7.2,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2025-07-11T11:50:32.196693Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2025-07-11T10:08:36.560Z",
    "assigner_short_name": "schneider"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.