nday
CVE-2025-40743

Siemens SINUMERIK 828D PPU.4: authentication bypassTitle composed by nday; the CVE record has none.

Siemens / SINUMERIK 828D PPU.4, SINUMERIK 828D PPU.5, SINUMERIK 840D sl, SINUMERIK MC, SINUMERIK MC V1.15, SINUMERIK ONE +1

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

authentication bypass
CWE-288, stated by the CNA siemens and NVD, republishing [email protected]
adjacent network
AV:A in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
no authentication required
PR:N in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
stage
DIS
disclosed
cvss
8.7 HIGH v4.0

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2025-08-12T11:17Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:A
Adjacent: only from a nearby network, such as the same LAN segment or Bluetooth range
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

Event log

+DISdisclosed

CVE record published by siemens. CVSS 8.7, high.

src cvelist · nday , bulk import · raw
{
  "id": 375992,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2025-40743",
  "occurred_at": "2025-08-12T11:17:03.997Z",
  "observed_at": "2026-11-13T05:39:08.090137Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 8.7,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2025-08-12T13:31:42.534312Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2025-08-12T11:17:03.997Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.