nday
CVE-2025-27769

A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions <…Title composed by nday; the CVE record has none.

Siemens / Heliox Flex 180 kW EV Charging Station, Heliox Mobile DC 40 kW EV Charging Station

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

physical
AV:P in CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N (CVSS 4.0) from the CNA siemens
no authentication required
PR:N in CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N (CVSS 4.0) from the CNA siemens
stage
DIS
disclosed
cvss
2.4 LOW v4.0

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
03-10T16:07Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:P
Physical: needs physical access to the device
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

Event log

+DISdisclosed

CVE record published by siemens. CVSS 2.4, low.

src cvelist · nday , bulk import · raw
{
  "id": 369058,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2025-27769",
  "occurred_at": "2026-03-10T16:07:43.641Z",
  "observed_at": "2026-11-13T05:39:03.77836Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
      "version": "4.0",
      "base_score": 2.4,
      "base_severity": "LOW"
    },
    "ssvc": {
      "timestamp": "2026-03-10T16:33:20.023387Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2026-03-10T16:07:43.641Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.