nday
CVE-2023-53168

usb: ucsi_acpi: Increase the command completion timeout

Linux / Linux

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

NULL pointer dereference
CWE-476, stated by NVD's analysts
local
AV:L in CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
Linux kernel
affected products in the CVE record: Linux · LinuxCPE names NVD's analysts give as vulnerable: o:linux:linux_kernel
operating system
affected products in the CVE record: Linux · LinuxCPE names NVD's analysts give as vulnerable: o:linux:linux_kernelthe product type of Linux kernel in nday's product registry
stage
DIS
disclosed
cvss
no score yet

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2025-09-15T14:03Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

In the Linux kernel, the following vulnerability has been resolved:

usb: ucsi_acpi: Increase the command completion timeout

Commit 130a96d698d7 ("usb: typec: ucsi: acpi: Increase command completion timeout value") increased the timeout from 5 seconds to 60 seconds due to issues related to alternate mode discovery.

After the alternate mode discovery switch to polled mode the timeout was reduced, but instead of being set back to 5 seconds it was reduced to 1 second.

This is causing problems when using a Lenovo ThinkPad X1 yoga gen7 connected over Type-C to a LG 27UL850-W (charging DP over Type-C).

When the monitor is already connected at boot the following error is logged: "PPM init failed (-110)", /sys/class/typec is empty and on unplugging the NULL pointer deref fixed earlier in this series happens.

When the monitor is connected after boot the following error is logged instead: "GET_CONNECTOR_STATUS failed (-110)".

Setting the timeout back to 5 seconds fixes both cases.

Original text of the CVE record (cvelist), shown as published.

Event log

+DISdisclosed

CVE record published by Linux.

src cvelist · nday , bulk import · raw
{
  "id": 2450,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2023-53168",
  "occurred_at": "2025-09-15T14:03:59.766Z",
  "observed_at": "2026-11-12T14:10:31.286634Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "ssvc": {
      "timestamp": "2026-11-05T20:19:27.330921Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2025-09-15T14:03:59.766Z",
    "assigner_short_name": "Linux"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.