nday
CVE-2022-28329

A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE…Title composed by nday; the CVE record has none.

Siemens / SCALANCE W1788-1 M12, SCALANCE W1788-2 EEC M12, SCALANCE W1788-2 M12, SCALANCE W1788-2IA M12

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

adjacent network
AV:A in CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
Siemens SCALANCE
affected products in the CVE record: Siemens · SCALANCE W1788-1 M12, Siemens · SCALANCE W1788-2 EEC M12, Siemens · SCALANCE W1788-2 M12, Siemens · SCALANCE W1788-2IA M12CPE names NVD's analysts give as vulnerable: o:siemens:scalance_w1788-1_m12_firmware, o:siemens:scalance_w1788-2_eec_m12_firmware, o:siemens:scalance_w1788-2_m12_firmware, o:siemens:scalance_w1788-2ia_m12_firmware
router / switch
affected products in the CVE record: Siemens · SCALANCE W1788-1 M12, Siemens · SCALANCE W1788-2 EEC M12, Siemens · SCALANCE W1788-2 M12, Siemens · SCALANCE W1788-2IA M12CPE names NVD's analysts give as vulnerable: o:siemens:scalance_w1788-1_m12_firmware, o:siemens:scalance_w1788-2_eec_m12_firmware, o:siemens:scalance_w1788-2_m12_firmware, o:siemens:scalance_w1788-2ia_m12_firmwarethe product type of Siemens SCALANCE in nday's product registry
ICS / OT
affected products in the CVE record: Siemens · SCALANCE W1788-1 M12, Siemens · SCALANCE W1788-2 EEC M12, Siemens · SCALANCE W1788-2 M12, Siemens · SCALANCE W1788-2IA M12CPE names NVD's analysts give as vulnerable: o:siemens:scalance_w1788-1_m12_firmware, o:siemens:scalance_w1788-2_eec_m12_firmware, o:siemens:scalance_w1788-2_m12_firmware, o:siemens:scalance_w1788-2ia_m12_firmwarethe product type of Siemens SCALANCE in nday's product registry
stage
DIS
disclosed
cvss
no score yet

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2022-04-12T09:08Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature.

Original text of the CVE record (cvelist), shown as published.

Event log

+DISdisclosed

CVE record published by siemens.

src cvelist · nday , bulk import · raw
{
  "id": 264657,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-28329",
  "occurred_at": "2022-04-12T09:08:07Z",
  "observed_at": "2026-11-13T05:37:40.655522Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2022-04-12T09:08:07.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.