nday
CVE-2022-25751

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V…Title composed by nday; the CVE record has none.

Siemens / SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated) +45

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
Siemens SCALANCE
affected products in the CVE record: Siemens · SCALANCE X302-7 EEC (230V), Siemens · SCALANCE X302-7 EEC (230V, coated), Siemens · SCALANCE X302-7 EEC (24V), Siemens · SCALANCE X302-7 EEC (24V, coated), Siemens · SCALANCE X302-7 EEC (2x 230V), Siemens · SCALANCE X302-7 EEC (2x 230V, coated), Siemens · SCALANCE X302-7 EEC (2x 24V), Siemens · SCALANCE X302-7 EEC (2x 24V, coated), Siemens · SCALANCE X304-2FE, Siemens · SCALANCE X306-1LD FE and 41 moreCPE names NVD's analysts give as vulnerable: o:siemens:scalance_x302-7eec_firmware, o:siemens:scalance_x304-2fe_firmware, o:siemens:scalance_x306-1ldfe_firmware, o:siemens:scalance_x307-2eec_firmware, o:siemens:scalance_x307-3_firmware, o:siemens:scalance_x307-3ld_firmware, o:siemens:scalance_x308-2_firmware, o:siemens:scalance_x308-2ld_firmware, o:siemens:scalance_x308-2lh+_firmware, o:siemens:scalance_x308-2lh_firmware and 13 more
router / switch
affected products in the CVE record: Siemens · SCALANCE X302-7 EEC (230V), Siemens · SCALANCE X302-7 EEC (230V, coated), Siemens · SCALANCE X302-7 EEC (24V), Siemens · SCALANCE X302-7 EEC (24V, coated), Siemens · SCALANCE X302-7 EEC (2x 230V), Siemens · SCALANCE X302-7 EEC (2x 230V, coated), Siemens · SCALANCE X302-7 EEC (2x 24V), Siemens · SCALANCE X302-7 EEC (2x 24V, coated), Siemens · SCALANCE X304-2FE, Siemens · SCALANCE X306-1LD FE and 41 moreCPE names NVD's analysts give as vulnerable: o:siemens:scalance_x302-7eec_firmware, o:siemens:scalance_x304-2fe_firmware, o:siemens:scalance_x306-1ldfe_firmware, o:siemens:scalance_x307-2eec_firmware, o:siemens:scalance_x307-3_firmware, o:siemens:scalance_x307-3ld_firmware, o:siemens:scalance_x308-2_firmware, o:siemens:scalance_x308-2ld_firmware, o:siemens:scalance_x308-2lh+_firmware, o:siemens:scalance_x308-2lh_firmware and 13 morethe product type of Siemens SCALANCE in nday's product registry
ICS / OT
affected products in the CVE record: Siemens · SCALANCE X302-7 EEC (230V), Siemens · SCALANCE X302-7 EEC (230V, coated), Siemens · SCALANCE X302-7 EEC (24V), Siemens · SCALANCE X302-7 EEC (24V, coated), Siemens · SCALANCE X302-7 EEC (2x 230V), Siemens · SCALANCE X302-7 EEC (2x 230V, coated), Siemens · SCALANCE X302-7 EEC (2x 24V), Siemens · SCALANCE X302-7 EEC (2x 24V, coated), Siemens · SCALANCE X304-2FE, Siemens · SCALANCE X306-1LD FE and 41 moreCPE names NVD's analysts give as vulnerable: o:siemens:scalance_x302-7eec_firmware, o:siemens:scalance_x304-2fe_firmware, o:siemens:scalance_x306-1ldfe_firmware, o:siemens:scalance_x307-2eec_firmware, o:siemens:scalance_x307-3_firmware, o:siemens:scalance_x307-3ld_firmware, o:siemens:scalance_x308-2_firmware, o:siemens:scalance_x308-2ld_firmware, o:siemens:scalance_x308-2lh+_firmware, o:siemens:scalance_x308-2lh_firmware and 13 morethe product type of Siemens SCALANCE in nday's product registry
stage
DIS
disclosed
cvss
no score yet

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2022-04-12T09:07Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.

Original text of the CVE record (cvelist), shown as published.

Event log

+DISdisclosed

CVE record published by siemens.

src cvelist · nday , bulk import · raw
{
  "id": 262875,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-25751",
  "occurred_at": "2022-04-12T09:07:43Z",
  "observed_at": "2026-11-13T05:37:39.263299Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2022-04-12T09:07:43.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.