nday
CVE-2020-29567

Xen: resource exhaustionTitle composed by nday; the CVE record has none.

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

resource exhaustion
CWE-770, stated by NVD's analysts
local
AV:L in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
Xen
CPE names NVD's analysts give as vulnerable: o:xen:xen
virtualization / containers
CPE names NVD's analysts give as vulnerable: o:xen:xenthe product type of Xen in nday's product registry
stage
DIS
disclosed
cvss
no score yet

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2020-12-15T16:50Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

An issue was discovered in Xen 4.14.x. When moving IRQs between CPUs to distribute the load of IRQ handling, IRQ vectors are dynamically allocated and de-allocated on the relevant CPUs. De-allocation has to happen when certain constraints are met. If these conditions are not met when first checked, the checking CPU may send an interrupt to itself, in the expectation that this IRQ will be delivered only after the condition preventing the cleanup has cleared. For two specific IRQ vectors, this expectation was violated, resulting in a continuous stream of self-interrupts, which renders the CPU effectively unusable. A domain with a passed through PCI device can cause lockup of a physical CPU, resulting in a Denial of Service (DoS) to the entire host. Only x86 systems are vulnerable. Arm systems are not vulnerable. Only guests with physical PCI devices passed through to them can exploit the vulnerability.

Original text of the CVE record (cvelist), shown as published.

Event log

+DISdisclosed

CVE record published by mitre.

src cvelist · nday , bulk import · raw
{
  "id": 229525,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2020-29567",
  "occurred_at": "2020-12-15T16:50:37Z",
  "observed_at": "2026-11-13T05:37:14.715998Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2020-12-15T16:50:37.000Z",
    "assigner_short_name": "mitre"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.