nday
CVE-2020-12028

Rockwell Automation FactoryTalk View SE

Rockwell Automation / FactoryTalk View SE

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. Listed by 1 of 4 PoC sources: metasploit. Not in CISA KEV.

tags weakness typeauthentication bypass accessnetwork exploitationMetasploit product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

authentication bypass
CWE-306, stated by NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N (CVSS 3.1) from the CNA icscert
Metasploit
Metasploit modules exploit/windows/scada/rockwell_factorytalk_rce
ICS / OT
affected products in the CVE record: Rockwell Automation · FactoryTalk View SECPE names NVD's analysts give as vulnerable: a:rockwellautomation:factorytalk_viewnday's type rule vendor:rockwell
stage
POC
disclosed
cvss
7.3 HIGH v3.1

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2020-07-20T15:17Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
metasploit
ITWexploited
no record yet
KEVKEV
no record yet

Summary

In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:L
Low: ordinary user privileges
User interaction UI:R
Required: a user must do something, such as open a file or click a link

CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N

CVSS 3.1 vector from the CVE record, scored by the CNA icscert.

Event log

+DISdisclosed

CVE record published by icscert. CVSS 7.3, high.

src cvelist · nday , bulk import · raw
{
  "id": 64247,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2020-12028",
  "occurred_at": "2020-07-20T15:17:11.738Z",
  "observed_at": "2026-11-12T21:04:12.541754Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
      "version": "3.1",
      "base_score": 7.3,
      "base_severity": "HIGH"
    },
    "state": "PUBLISHED",
    "date_published": "2020-07-20T15:17:11.738Z",
    "assigner_short_name": "icscert"
  }
}
time unknownsource gave no time
+POCpublic PoC

Metasploit has module exploit/windows/scada/rockwell_factorytalk_rce (Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution). The source gives no release time for the module.

src metasploit exploit/windows/scada/rockwell_factorytalk_rce · nday , bulk import · raw
{
  "id": 52976,
  "type": "poc_published",
  "source": "metasploit",
  "url": "https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/windows/scada/rockwell_factorytalk_rce.rb",
  "occurred_at": null,
  "observed_at": "2026-11-12T15:24:51.477477Z",
  "is_backfill": true,
  "dedupe_key": "exploit/windows/scada/rockwell_factorytalk_rce",
  "detail": {
    "url": "https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/windows/scada/rockwell_factorytalk_rce.rb",
    "kind": "msf_module",
    "path": "/modules/exploits/windows/scada/rockwell_factorytalk_rce.rb",
    "rank": 600,
    "check": true,
    "title": "Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution",
    "cve_ids": [
      "CVE-2020-12027",
      "CVE-2020-12028",
      "CVE-2020-12029"
    ],
    "fullname": "exploit/windows/scada/rockwell_factorytalk_rce",
    "rank_name": "excellent",
    "confidence": "curated",
    "module_type": "exploit",
    "module_last_modified": "2026-04-22 11:58:58 +0000",
    "vuln_disclosure_date": "2020-06-22"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.