nday
CVE-2019-6821

Schneider Modicon: cryptographic failureTitle composed by nday; the CVE record has none.

Disclosed . nday has no fix record for it yet; that does not mean no patch exists. None of the four PoC sources lists it. Not in CISA KEV.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

cryptographic failure
CWE-330, stated by the CNA schneider, NVD's analysts, and NVD, republishing [email protected]
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N (CVSS 3.1) from NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N (CVSS 3.1) from NVD's analysts
Schneider Modicon
CPE names NVD's analysts give as vulnerable: o:schneider-electric:modicon_m340_firmware, o:schneider-electric:modicon_m580_firmware, o:schneider-electric:modicon_premium_firmware, o:schneider-electric:modicon_quantum_firmware
ICS / OT
CPE names NVD's analysts give as vulnerable: o:schneider-electric:modicon_m340_firmware, o:schneider-electric:modicon_m580_firmware, o:schneider-electric:modicon_premium_firmware, o:schneider-electric:modicon_quantum_firmwarethe product type of Schneider Modicon in nday's product registrynday's type rule vendor:schneider-electric
stage
DIS
disclosed
cvss
no score yet

Lifecycle

x axis UTC; dot = exact minute, wide bar = date only, hollow = unknown or inferred.
time unknown
DISdisclosed
2019-05-22T19:42Z
PATpatch
no record yet
ANAanalysis
no record yet
POCPoC
no record yet
ITWexploited
no record yet
KEVKEV
no record yet

Summary

CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum.

Original text of the CVE record (cvelist), shown as published.

Event log

+DISdisclosed

CVE record published by schneider.

src cvelist · nday , bulk import · raw
{
  "id": 199334,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2019-6821",
  "occurred_at": "2019-05-22T19:42:06Z",
  "observed_at": "2026-11-13T05:36:54.581922Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2019-05-22T19:42:06.000Z",
    "assigner_short_name": "schneider"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Researcher discussion

0 researchers mentioned this in the last 7 days

Posts on X by researchers on nday's list that mention this CVE, shown as posted. nday does not check them.

nday has not collected any post on X by listed researchers that mentions this CVE.

Discussion

0 comments

No comments yet.