nday
CVE-2026-5667

Information Disclosure, Information Tampering, or Denial-of-Service (DoS) Vulnerability in Multiple Home Appliances

Mitsubishi Electric Corporation / Room Air Conditioners (for Japan) MSZ-BKR2223-W, Room Air Conditioners (for Japan) MSZ-BKR2224-W, Room Air Conditioners (for Japan) MSZ-BKR2523-W, Room Air Conditioners (for Japan) MSZ-BKR2524-W, Room Air Conditioners (for Japan) MSZ-BKR2823-W, Room Air Conditioners (for Japan) MSZ-BKR2824-W +2474

CVE 공개: . nday가 아직 패치 근거를 수집하지 않았습니다. 패치가 없다는 뜻은 아닙니다. PoC 출처 4곳 모두 미등재. CISA KEV 미등재.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

hard-coded credentials
CWE-798, stated by the CNA Mitsubishi 및 NVD, republishing [email protected]
adjacent network
AV:A in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA Mitsubishi
no authentication required
PR:N in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA Mitsubishi
no user interaction
UI:N in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA Mitsubishi
camera / IoT device
affected products in the CVE record: Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Adapters for Airflow Ventilation Systems, Heat Pump Chilled/Hot Water Systems, and Ventilation/Air-Conditioning System …, Mitsubishi Electric Corporation · Heat Pump Water Heaters / HEMS-Compatible Adapters / Wireless LAN Adapters (for Japan) GT-HEM4 and 2,459 morenday's type rule mitsubishi:appliance
현재 단계
DIS
공개
CVSS
7.2 HIGH v4.0

생명주기

가로축 UTC. 점 = 분 단위, 넓은 막대 = 날짜만, 빈 표시 = 불명 또는 추정.
시점 알 수 없음
DIS공개
06-17T10:53Z
PAT패치
아직 기록 없음
ANA분석
아직 기록 없음
POCPoC
아직 기록 없음
ITW악용
아직 기록 없음
KEVKEV
아직 기록 없음

요약

Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Room Air Conditioners (for Japan and outside Japan); Wireless LAN Adapters for Packaged Air Conditioners (for Japan and outside Japan); Refrigerators (for Japan); Heat Pump Water Heaters / HEMS-Compatible Adapters / Wireless LAN Adapters (for Japan); Bathroom Dryer / Heater / Ventilation Systems (for Japan); Adapters for Airflow Ventilation Systems, Heat Pump Chilled / Hot Water Systems, and Ventilation / Air-Conditioning System Air Resorts (for Japan); Lossnay Central Ventilation Systems (for Japan); Smart Switches for Ventilation Fans and Lossnay (for Japan); IH Cooking Heaters (for Japan); and Rice Cookers (for Japan) allows an attacker within Wi-Fi radio range of an affected product to access the affected product using a hard-coded SSID and password, thereby obtaining device data such as operation status, room set temperature, and room temperature; changing the air-conditioner or Wi-Fi settings; or causing Wi-Fi communication to enter a denial-of-service (DoS) condition.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:A
Adjacent: only from a nearby network, such as the same LAN segment or Bluetooth range
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA Mitsubishi.

이벤트 로그

+DISCVE 공개

CVE 레코드 공개(CNA: Mitsubishi). CVSS 7.2(높음).

출처 cvelist · nday 일괄 수집 · 원본
{
  "id": 397604,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2026-5667",
  "occurred_at": "2026-06-17T10:53:53.8Z",
  "observed_at": "2026-11-13T05:39:25.012947Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 7.2,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2026-06-17T12:05:33.246758Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2026-06-17T10:53:53.800Z",
    "assigner_short_name": "Mitsubishi"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

연구자 논의

최근 7일간 연구자 0명이 언급

목록의 연구자가 X에서 이 CVE를 언급한 게시물입니다. 원문 그대로 보여 주며 nday는 검증하지 않습니다.

명단의 연구자가 X에서 이 CVE를 언급한 게시물은 아직 수집되지 않았습니다.

Discussion

0 comments

No comments yet.