nday
CVE-2020-7581

Siemens SIMATIC: uncontrolled search pathnday가 생성한 제목입니다. CVE 레코드에는 제목이 없습니다.

Siemens / Opcenter Execution Discrete, Opcenter Execution Foundation, Opcenter Execution Process, Opcenter Intelligence, Opcenter Quality, Opcenter RD&L +8

CVE 공개: . nday가 아직 패치 근거를 수집하지 않았습니다. 패치가 없다는 뜻은 아닙니다. PoC 출처 4곳 모두 미등재. CISA KEV 미등재.

tags weakness typeuncontrolled search path accesslocalno user interaction productSiemens SIMATIC product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

uncontrolled search path
CWE-428, stated by the CNA siemens, NVD's analysts 및 NVD, republishing [email protected]
local
AV:L in CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC Notifier Server for Windows, Siemens · SIMATIC PCS neo, Siemens · SIMATIC STEP 7 (TIA Portal) V15, Siemens · SIMATIC STEP 7 (TIA Portal) V16CPE names NVD's analysts give as vulnerable: a:siemens:simatic_notifier_server, a:siemens:simatic_pcs_neo, a:siemens:simatic_step_7
ICS / OT
affected products in the CVE record: Siemens · SIMATIC Notifier Server for Windows, Siemens · SIMATIC PCS neo, Siemens · SIMATIC STEP 7 (TIA Portal) V15, Siemens · SIMATIC STEP 7 (TIA Portal) V16CPE names NVD's analysts give as vulnerable: a:siemens:simatic_notifier_server, a:siemens:simatic_pcs_neo, a:siemens:simatic_step_7the product type of Siemens SIMATIC in nday's product registry
현재 단계
DIS
공개
CVSS
점수 없음

생명주기

가로축 UTC. 점 = 분 단위, 넓은 막대 = 날짜만, 빈 표시 = 불명 또는 추정.
시점 알 수 없음
DIS공개
2020-07-14T13:18Z
PAT패치
아직 기록 없음
ANA분석
아직 기록 없음
POCPoC
아직 기록 없음
ITW악용
아직 기록 없음
KEVKEV
아직 기록 없음

요약

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.

Original text of the CVE record (cvelist), shown as published.

이벤트 로그

+DISCVE 공개

CVE 레코드 공개(CNA: siemens).

출처 cvelist · nday 일괄 수집 · 원본
{
  "id": 217229,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2020-7581",
  "occurred_at": "2020-07-14T13:18:05Z",
  "observed_at": "2026-11-13T05:37:07.508084Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2020-07-14T13:18:05.000Z",
    "assigner_short_name": "siemens"
  }
}