Siemens / SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V) +50

CVE 공개: . nday가 아직 패치 근거를 수집하지 않았습니다. 패치가 없다는 뜻은 아닙니다. PoC 출처 4곳 모두 미등재. CISA KEV 미등재.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

authentication bypass
CWE-306, stated by the CNA siemens, NVD's analysts 및 NVD, republishing [email protected]
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L (CVSS 3.1) from NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L (CVSS 3.1) from NVD's analysts
Siemens SCALANCE
affected products in the CVE record: Siemens · SCALANCE X204RNA (HSR), Siemens · SCALANCE X204RNA (PRP), Siemens · SCALANCE X204RNA EEC (HSR), Siemens · SCALANCE X204RNA EEC (PRP), Siemens · SCALANCE X204RNA EEC (PRP/HSR), Siemens · SCALANCE X302-7 EEC (230V), Siemens · SCALANCE X302-7 EEC (230V, coated), Siemens · SCALANCE X302-7 EEC (24V), Siemens · SCALANCE X302-7 EEC (24V, coated), Siemens · SCALANCE X302-7 EEC (2x 230V) and 46 moreCPE names NVD's analysts give as vulnerable: o:siemens:scalance_x-200rna_firmware, o:siemens:scalance_x-300_firmware, o:siemens:scalance_x204rna_firmware, o:siemens:scalance_x408-2_firmware, o:siemens:scalance_xr-300_firmware, o:siemens:scalance_xr-300wg_firmware
router / switch
affected products in the CVE record: Siemens · SCALANCE X204RNA (HSR), Siemens · SCALANCE X204RNA (PRP), Siemens · SCALANCE X204RNA EEC (HSR), Siemens · SCALANCE X204RNA EEC (PRP), Siemens · SCALANCE X204RNA EEC (PRP/HSR), Siemens · SCALANCE X302-7 EEC (230V), Siemens · SCALANCE X302-7 EEC (230V, coated), Siemens · SCALANCE X302-7 EEC (24V), Siemens · SCALANCE X302-7 EEC (24V, coated), Siemens · SCALANCE X302-7 EEC (2x 230V) and 46 moreCPE names NVD's analysts give as vulnerable: o:siemens:scalance_x-200rna_firmware, o:siemens:scalance_x-300_firmware, o:siemens:scalance_x204rna_firmware, o:siemens:scalance_x408-2_firmware, o:siemens:scalance_xr-300_firmware, o:siemens:scalance_xr-300wg_firmwarethe product type of Siemens SCALANCE in nday's product registry
ICS / OT
affected products in the CVE record: Siemens · SCALANCE X204RNA (HSR), Siemens · SCALANCE X204RNA (PRP), Siemens · SCALANCE X204RNA EEC (HSR), Siemens · SCALANCE X204RNA EEC (PRP), Siemens · SCALANCE X204RNA EEC (PRP/HSR), Siemens · SCALANCE X302-7 EEC (230V), Siemens · SCALANCE X302-7 EEC (230V, coated), Siemens · SCALANCE X302-7 EEC (24V), Siemens · SCALANCE X302-7 EEC (24V, coated), Siemens · SCALANCE X302-7 EEC (2x 230V) and 46 moreCPE names NVD's analysts give as vulnerable: o:siemens:scalance_x-200rna_firmware, o:siemens:scalance_x-300_firmware, o:siemens:scalance_x204rna_firmware, o:siemens:scalance_x408-2_firmware, o:siemens:scalance_xr-300_firmware, o:siemens:scalance_xr-300wg_firmwarethe product type of Siemens SCALANCE in nday's product registry
현재 단계
DIS
공개
CVSS
점수 없음

생명주기

가로축 UTC. 점 = 분 단위, 넓은 막대 = 날짜만, 빈 표시 = 불명 또는 추정.
시점 알 수 없음
DIS공개
2020-01-16T00:00Z
PAT패치
아직 기록 없음
ANA분석
아직 기록 없음
POCPoC
아직 기록 없음
ITW악용
아직 기록 없음
KEVKEV
아직 기록 없음

요약

A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.

Original text of the CVE record (cvelist), shown as published.

이벤트 로그

+DISCVE 공개

CVE 레코드 공개(CNA: siemens).

출처 cvelist · nday 일괄 수집 · 원본
{
  "id": 204705,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2019-13933",
  "occurred_at": "2020-01-16T00:00:00Z",
  "observed_at": "2026-11-13T05:36:58.202694Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2020-01-16T00:00:00.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

연구자 논의

최근 7일간 연구자 0명이 언급

목록의 연구자가 X에서 이 CVE를 언급한 게시물입니다. 원문 그대로 보여 주며 nday는 검증하지 않습니다.

명단의 연구자가 X에서 이 CVE를 언급한 게시물은 아직 수집되지 않았습니다.

Discussion

0 comments

No comments yet.