nday
CVE-2019-10929

Siemens SIMATIC: cryptographic failurenday가 생성한 제목입니다. CVE 레코드에는 제목이 없습니다.

Siemens / SIMATIC CP 1626, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC HMI Panel (incl. SIPLUS variants), SIMATIC NET PC Software V14, SIMATIC NET PC Software V15 +10

CVE 공개: . nday가 아직 패치 근거를 수집하지 않았습니다. 패치가 없다는 뜻은 아닙니다. PoC 출처 4곳 모두 미등재. CISA KEV 미등재.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

cryptographic failure
CWE-327, stated by the CNA siemens 및 NVD, republishing [email protected]
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from NVD's analysts
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC CP 1626, Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), Siemens · SIMATIC HMI Panel (incl. SIPLUS variants), Siemens · SIMATIC NET PC Software V14, Siemens · SIMATIC NET PC Software V15, Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants), Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens · SIMATIC S7-1500 Software Controller, Siemens · SIMATIC S7-PLCSIM Advanced and 5 moreCPE names NVD's analysts give as vulnerable: o:siemens:simatic_cp_1626_firmware, o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware, o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware, o:siemens:simatic_hmi_panel_firmware, a:siemens:simatic_net_pc, o:siemens:simatic_s7-1200_cpu_1211c_firmware, o:siemens:simatic_s7-1200_cpu_1212c_firmware, o:siemens:simatic_s7-1200_cpu_1214c_firmware, o:siemens:simatic_s7-1200_cpu_1215c_firmware, o:siemens:simatic_s7-1200_cpu_1217c_firmware and 10 more
ICS / OT
affected products in the CVE record: Siemens · SIMATIC CP 1626, Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), Siemens · SIMATIC HMI Panel (incl. SIPLUS variants), Siemens · SIMATIC NET PC Software V14, Siemens · SIMATIC NET PC Software V15, Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants), Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens · SIMATIC S7-1500 Software Controller, Siemens · SIMATIC S7-PLCSIM Advanced and 5 moreCPE names NVD's analysts give as vulnerable: o:siemens:simatic_cp_1626_firmware, o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware, o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware, o:siemens:simatic_hmi_panel_firmware, a:siemens:simatic_net_pc, o:siemens:simatic_s7-1200_cpu_1211c_firmware, o:siemens:simatic_s7-1200_cpu_1212c_firmware, o:siemens:simatic_s7-1200_cpu_1214c_firmware, o:siemens:simatic_s7-1200_cpu_1215c_firmware, o:siemens:simatic_s7-1200_cpu_1217c_firmware and 10 morethe product type of Siemens SIMATIC in nday's product registry
현재 단계
DIS
공개
CVSS
점수 없음

생명주기

가로축 UTC. 점 = 분 단위, 넓은 막대 = 날짜만, 빈 표시 = 불명 또는 추정.
시점 알 수 없음
DIS공개
2019-08-13T18:55Z
PAT패치
아직 기록 없음
ANA분석
아직 기록 없음
POCPoC
아직 기록 없음
ITW악용
아직 기록 없음
KEVKEV
아직 기록 없음

요약

A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.

Original text of the CVE record (cvelist), shown as published.

이벤트 로그

+DISCVE 공개

CVE 레코드 공개(CNA: siemens).

출처 cvelist · nday 일괄 수집 · 원본
{
  "id": 202472,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2019-10929",
  "occurred_at": "2019-08-13T18:55:57Z",
  "observed_at": "2026-11-13T05:36:55.820159Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2019-08-13T18:55:57.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

연구자 논의

최근 7일간 연구자 0명이 언급

목록의 연구자가 X에서 이 CVE를 언급한 게시물입니다. 원문 그대로 보여 주며 nday는 검증하지 않습니다.

명단의 연구자가 X에서 이 CVE를 언급한 게시물은 아직 수집되지 않았습니다.

Discussion

0 comments

No comments yet.