nday
CVE-2026-54429

Siemens SIMATIC:resource exhaustionnday が生成したタイトルです(CVE レコードにタイトルなし)。

Siemens / SIMATIC S7-PLCSIM Advanced

に公開されました。nday はまだ修正の根拠を取得していません。修正がないという意味ではありません。4 つの PoC ソースのいずれにも未掲載です。CISA KEV には現時点で未掲載です。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

resource exhaustion
CWE-770, stated by the CNA siemens、NVD, republishing [email protected]
adjacent network
AV:A in CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L (CVSS 4.0) from the CNA siemens
no authentication required
PR:N in CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC S7-PLCSIM Advanced
ICS / OT
affected products in the CVE record: Siemens · SIMATIC S7-PLCSIM Advancedthe product type of Siemens SIMATIC in nday's product registry
現在の段階
DIS
公開日時
CVSS 基本値
6.0 MEDIUM v4.0

ライフサイクル

横軸は UTC。点=分単位、幅広の帯=日付のみ、白抜き=不明または推定。
日時不明
DIS公開
07-14T09:19Z
PAT修正
記録なし
ANA解析
記録なし
POCPoC
記録なし
ITW悪用
記録なし
KEVKEV
記録なし

概要

A vulnerability has been identified in SIMATIC S7-PLCSIM Advanced (All versions). Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-service condition of the affected application. The affected application becomes inaccessible and requires a manual restart; no project data is lost. Successful exploitation requires a specific project configuration to be already active on the targeted instance.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:A
Adjacent: only from a nearby network, such as the same LAN segment or Bluetooth range
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:P
Present: success depends on specific deployment or execution conditions, such as a race condition, a non-default setting or a position on the network path
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

イベント履歴

+DIS公開

siemens が CVE レコードを公開。CVSS 基本値 6(警告)。

出典 cvelist · nday が に一括取り込み · 生データ
{
  "id": 431051,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2026-54429",
  "occurred_at": "2026-07-14T09:19:17.249Z",
  "observed_at": "2026-11-13T05:39:55.731897Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L",
      "version": "4.0",
      "base_score": 6,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2026-07-14T12:15:03.571205Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2026-07-14T09:19:17.249Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究者の投稿

過去 7 日間に 0 人の研究者が言及

リストの研究者が X でこの CVE に触れた投稿です。原文のまま表示し、nday は検証していません。

リストの研究者が X でこの CVE に触れた投稿は、まだ収集していません。

Discussion

0 comments

No comments yet.