nday
CVE-2024-10497

Schneider Electric PowerLogic HDPM6000:broken access controlnday が生成したタイトルです(CVE レコードにタイトルなし)。

Schneider Electric / PowerLogic HDPM6000

に公開されました。nday はまだ修正の根拠を取得していません。修正がないという意味ではありません。4 つの PoC ソースのいずれにも未掲載です。CISA KEV には現時点で未掲載です。

tags weakness typebroken access control accessnetworkno user interaction product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

broken access control
CWE-639, stated by the CNA schneider、NVD, republishing [email protected]
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA schneider
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA schneider
ICS / OT
affected products in the CVE record: Schneider Electric · PowerLogic HDPM6000nday's type rule vendor:schneider-electric
現在の段階
DIS
公開日時
CVSS 基本値
8.7 HIGH v4.0

ライフサイクル

横軸は UTC。点=分単位、幅広の帯=日付のみ、白抜き=不明または推定。
日時不明
DIS公開
2025-01-17T10:27Z
PAT修正
記録なし
ANA解析
記録なし
POCPoC
記録なし
ITW悪用
記録なし
KEVKEV
記録なし

概要

CWE-639: Authorization Bypass Through User-Controlled Key vulnerability exists that could allow an authorized attacker to modify values outside those defined by their privileges (Elevation of Privileges) when the attacker sends modified HTTPS requests to the device.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:L
Low: ordinary user privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA schneider.

イベント履歴

+DIS公開

schneider が CVE レコードを公開。CVSS 基本値 8.7(重要)。

出典 cvelist · nday が に一括取り込み · 生データ
{
  "id": 320139,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2024-10497",
  "occurred_at": "2025-01-17T10:27:52.954Z",
  "observed_at": "2026-11-13T05:38:22.620224Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 8.7,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2025-01-17T13:14:24.860170Z",
      "automatable": "yes",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2025-01-17T10:27:52.954Z",
    "assigner_short_name": "schneider"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究者の投稿

過去 7 日間に 0 人の研究者が言及

リストの研究者が X でこの CVE に触れた投稿です。原文のまま表示し、nday は検証していません。

リストの研究者が X でこの CVE に触れた投稿は、まだ収集していません。

Discussion

0 comments

No comments yet.