Siemens APOGEE PXC Compact (BACnet):buffer overflow / out-of-bounds writenday が生成したタイトルです(CVE レコードにタイトルなし)。

Siemens / APOGEE PXC Compact (BACnet)、APOGEE PXC Compact (P2 Ethernet)、APOGEE PXC Modular (BACnet)、APOGEE PXC Modular (P2 Ethernet)、Nucleus NET、Nucleus ReadyStart V3 +5

に公開されました。nday はまだ修正の根拠を取得していません。修正がないという意味ではありません。4 つの PoC ソースのいずれにも未掲載です。CISA KEV には現時点で未掲載です。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

buffer overflow / out-of-bounds write
CWE-119, stated by NVD's analystsCWE-788, stated by the CNA siemens、NVD, republishing [email protected]
remote, unauthenticated
AV:N、PR:N、UI:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
network
AV:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no authentication required
PR:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no user interaction
UI:N in CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
現在の段階
DIS
公開日時
CVSS 基本値
6.5 MEDIUM v3.1

ライフサイクル

横軸は UTC。点=分単位、幅広の帯=日付のみ、白抜き=不明または推定。
日時不明
DIS公開
2021-04-22T20:42Z
PAT修正
記録なし
ANA解析
記録なし
POCPoC
記録なし
ITW悪用
記録なし
KEVKEV
記録なし

概要

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:H
High: success depends on conditions outside the attacker's control, such as gathering details of the target or winning a race
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C

CVSS 3.1 vector from the CVE record, scored by the CNA siemens.

イベント履歴

+DIS公開

siemens が CVE レコードを公開。CVSS 基本値 6.5(警告)。

出典 cvelist · nday が に一括取り込み · 生データ
{
  "id": 228569,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2020-27738",
  "occurred_at": "2021-04-22T20:42:20Z",
  "observed_at": "2026-11-13T05:37:13.444896Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
      "version": "3.1",
      "base_score": 6.5,
      "base_severity": "MEDIUM"
    },
    "state": "PUBLISHED",
    "date_published": "2021-04-22T20:42:20.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究者の投稿

過去 7 日間に 0 人の研究者が言及

リストの研究者が X でこの CVE に触れた投稿です。原文のまま表示し、nday は検証していません。

リストの研究者が X でこの CVE に触れた投稿は、まだ収集していません。

Discussion

0 comments

No comments yet.