CVE-2017-10722

Recently it was discovered as a part of the research on IoT devices in the most recent firmware…nday が生成したタイトルです(CVE レコードにタイトルなし)。

に公開されました。nday はまだ修正の根拠を取得していません。修正がないという意味ではありません。4 つの PoC ソースのいずれにも未掲載です。CISA KEV には現時点で未掲載です。

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

local
AV:L in CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (CVSS 3.0) from NVD's analysts
no user interaction
UI:N in CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (CVSS 3.0) from NVD's analysts
現在の段階
DIS
公開日時
CVSS 基本値
スコアなし

ライフサイクル

横軸は UTC。点=分単位、幅広の帯=日付のみ、白抜き=不明または推定。
日時不明
DIS公開
2019-06-17T21:39Z
PAT修正
記録なし
ANA解析
記録なし
POCPoC
記録なし
ITW悪用
記録なし
KEVKEV
記録なし

概要

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is installed on the device and an attacker who can provide the right payload can execute code on the user's system directly. Any breach of this system can allow an attacker to get access to all the data that the user has access too. The application uses a dynamic link library(DLL) called "avilib.dll" which is used by the application to send binary packets to the device that allow to control the device. One such action that the DLL provides is change password in the function "sendchangepass" which allows a user to change the Wi-Fi password on the device. This function calls a sub function "sub_75876EA0" at address 0x7587857C. The function determines which action to execute based on the parameters sent to it. The "sendchangepass" passes the datastring as the second argument which is the password we enter in the textbox and integer 2 as first argument. The rest of the 3 arguments are set to 0. The function "sub_75876EA0" at address 0x75876F19 uses the first argument received and to determine which block to jump to. Since the argument passed is 2, it jumps to 0x7587718C and proceeds from there to address 0x758771C2 which calculates the length of the data string passed as the first parameter.This length and the first argument are then passed to the address 0x7587726F which calls a memmove function which uses a stack address as the destination where the password typed by us is passed as the source and length calculated above is passed as the number of bytes to copy which leads to a stack overflow.

Original text of the CVE record (cvelist), shown as published.

イベント履歴

+DIS公開

mitre が CVE レコードを公開。

出典 cvelist · nday が に一括取り込み · 生データ
{
  "id": 170451,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2017-10722",
  "occurred_at": "2019-06-17T21:39:51Z",
  "observed_at": "2026-11-13T05:36:34.493672Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2019-06-17T21:39:51.000Z",
    "assigner_short_name": "mitre"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

研究者の投稿

過去 7 日間に 0 人の研究者が言及

リストの研究者が X でこの CVE に触れた投稿です。原文のまま表示し、nday は検証していません。

リストの研究者が X でこの CVE に触れた投稿は、まだ収集していません。

Discussion

0 comments

No comments yet.