nday
CVE-2025-9291

Improper Certificate Validation in TP-Link Omada Cloud Communications

TP-Link Systems Inc. / Omada Gateways, Omada Switches, Omada Access Points

Divulgation : . nday n’a encore aucune trace de correctif ; cela ne veut pas dire qu’il n’en existe pas. Cette vulnérabilité ne figure dans aucune des quatre sources de PoC. Aucune inscription au catalogue KEV de la CISA à ce jour.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

cryptographic failure
CWE-295, stated by the CNA TPLink et NVD, republishing f23511db-6c3e-4e32-a477-6aa17d310630
network
AV:N in CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA TPLink
no authentication required
PR:N in CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA TPLink
router / switch
affected products in the CVE record: TP-Link Systems Inc. · Omada Access Points, TP-Link Systems Inc. · Omada Gateways, TP-Link Systems Inc. · Omada SwitchesCPE names NVD's analysts give as vulnerable: o:tp-link:omada_ds1008x_firmware, o:tp-link:omada_ds1016g_firmware, o:tp-link:omada_ds1016ge_firmware, o:tp-link:omada_ds1018gmp_firmware, o:tp-link:omada_ds1024g_firmware, o:tp-link:omada_ds105g-m2_firmware, o:tp-link:omada_ds105g_firmware, o:tp-link:omada_ds105ge_firmware, o:tp-link:omada_ds105gp_firmware, o:tp-link:omada_ds105x_firmware and 99 morenday's type rule tp-link:network
étape actuelle
DIS
divulgation
CVSS
7.7 HIGH v4.0

Cycle de vie

Axe en UTC ; point = minute exacte, barre large = date seule, creux = inconnue ou déduite.
date inconnue
DISdivulguée
08-03T17:48Z
PATcorrectif
aucune donnée
ANAanalyse
aucune donnée
POCPoC
aucune donnée
ITWexploitée
aucune donnée
KEVKEV
aucune donnée

Résumé

A certification validation weakness exists in communication between affected Omada devices and cloud controllers. Certificate identity verification does not adequately validate that a presented certificate corresponds to the expected cloud controller hostname, which may allow certificate validation protections to be bypassed under specific conditions.

Successful exploitation may allow interception or modification of communication between affected devices and cloud controllers.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:H
High: the attacker must evade or get around security measures such as ASLR or DEP, or obtain target-specific secrets
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:P
Passive: limited, involuntary interaction, such as visiting a page

CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA TPLink.

Journal des événements

+DISdivulgation

Fiche CVE publiée par TPLink. CVSS 7.7, gravité élevée.

source cvelist · importé en masse par nday le · brut
{
  "id": 357141,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2025-9291",
  "occurred_at": "2026-08-03T17:48:14.707Z",
  "observed_at": "2026-11-13T05:38:53.618029Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 7.7,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2026-08-04T00:00:00+00:00",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2026-08-03T17:48:14.707Z",
    "assigner_short_name": "TPLink"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Échanges entre chercheurs

0 chercheur en a parlé ces 7 derniers jours

Publications sur X de chercheurs suivis par nday citant cette CVE, telles que publiées. nday ne les vérifie pas.

nday n’a encore recueilli aucune publication sur X d’un chercheur de sa liste citant cette CVE.

Discussion

0 comments

No comments yet.