nday
CVE-2023-46285

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407)…Titre composé par nday ; la fiche CVE n’en comporte pas.

Siemens / Opcenter Execution Foundation, Opcenter Quality, SIMATIC PCS neo, SINEC NMS, Totally Integrated Automation Portal (TIA Portal) V14, Totally Integrated Automation Portal (TIA Portal) V15.1 +3

Divulgation : . nday n’a encore aucune trace de correctif ; cela ne veut pas dire qu’il n’en existe pas. Cette vulnérabilité ne figure dans aucune des quatre sources de PoC. Aucune inscription au catalogue KEV de la CISA à ce jour.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC PCS neoCPE names NVD's analysts give as vulnerable: a:siemens:simatic_pcs_neo
ICS / OT
affected products in the CVE record: Siemens · SIMATIC PCS neoCPE names NVD's analysts give as vulnerable: a:siemens:simatic_pcs_neothe product type of Siemens SIMATIC in nday's product registry
étape actuelle
DIS
divulgation
CVSS
7.5 HIGH v3.1

Cycle de vie

Axe en UTC ; point = minute exacte, barre large = date seule, creux = inconnue ou déduite.
date inconnue
DISdivulguée
2023-12-12T11:27Z
PATcorrectif
aucune donnée
ANAanalyse
aucune donnée
POCPoC
aucune donnée
ITWexploitée
aucune donnée
KEVKEV
aucune donnée

Résumé

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C

CVSS 3.1 vector from the CVE record, scored by the CNA siemens.

Journal des événements

+DISdivulgation

Fiche CVE publiée par siemens. CVSS 7.5, gravité élevée.

source cvelist · importé en masse par nday le · brut
{
  "id": 304777,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2023-46285",
  "occurred_at": "2023-12-12T11:27:17.08Z",
  "observed_at": "2026-11-13T05:38:11.228551Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
      "version": "3.1",
      "base_score": 7.5,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2024-01-20T05:00:31.916630Z",
      "automatable": "yes",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2023-12-12T11:27:17.080Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Échanges entre chercheurs

0 chercheur en a parlé ces 7 derniers jours

Publications sur X de chercheurs suivis par nday citant cette CVE, telles que publiées. nday ne les vérifie pas.

nday n’a encore recueilli aucune publication sur X d’un chercheur de sa liste citant cette CVE.

Discussion

0 comments

No comments yet.