nday
CVE-2022-23449

Siemens SIMATIC : uncontrolled search pathTitre composé par nday ; la fiche CVE n’en comporte pas.

Siemens / SIMATIC Energy Manager Basic, SIMATIC Energy Manager PRO

Divulgation : . nday n’a encore aucune trace de correctif ; cela ne veut pas dire qu’il n’en existe pas. Cette vulnérabilité ne figure dans aucune des quatre sources de PoC. Aucune inscription au catalogue KEV de la CISA à ce jour.

tags weakness typeuncontrolled search path accesslocal productSiemens SIMATIC product typeICS / OT
why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

uncontrolled search path
CWE-427, stated by the CNA siemens, NVD's analysts et NVD, republishing [email protected]
local
AV:L in CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC Energy Manager Basic, Siemens · SIMATIC Energy Manager PROCPE names NVD's analysts give as vulnerable: a:siemens:simatic_energy_manager_basic, a:siemens:simatic_energy_manager_pro
ICS / OT
affected products in the CVE record: Siemens · SIMATIC Energy Manager Basic, Siemens · SIMATIC Energy Manager PROCPE names NVD's analysts give as vulnerable: a:siemens:simatic_energy_manager_basic, a:siemens:simatic_energy_manager_prothe product type of Siemens SIMATIC in nday's product registry
étape actuelle
DIS
divulgation
CVSS
pas encore de score

Cycle de vie

Axe en UTC ; point = minute exacte, barre large = date seule, creux = inconnue ou déduite.
date inconnue
DISdivulguée
2022-04-12T09:07Z
PATcorrectif
aucune donnée
ANAanalyse
aucune donnée
POCPoC
aucune donnée
ITWexploitée
aucune donnée
KEVKEV
aucune donnée

Résumé

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.

Original text of the CVE record (cvelist), shown as published.

Journal des événements

+DISdivulgation

Fiche CVE publiée par siemens.

source cvelist · importé en masse par nday le · brut
{
  "id": 261106,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-23449",
  "occurred_at": "2022-04-12T09:07:37Z",
  "observed_at": "2026-11-13T05:37:37.656355Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2022-04-12T09:07:37.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Échanges entre chercheurs

0 chercheur en a parlé ces 7 derniers jours

Publications sur X de chercheurs suivis par nday citant cette CVE, telles que publiées. nday ne les vérifie pas.

nday n’a encore recueilli aucune publication sur X d’un chercheur de sa liste citant cette CVE.

Discussion

0 comments

No comments yet.