nday
CVE-2021-22283

MMS File Transfer Vulnerability impact on Distribution Automation products

ABB / Relion protection relays - 611 series, Relion protection relays - 615 series IEC 4.0 FP1, Relion protection relays - 615 series CN 4.0 FP1, Relion protection relays - 615 series IEC 5.0, Relion protection relays - 615 series IEC 5.0 FP1, Relion protection relays - 620 series IEC/CN 2.0 +7

Divulgation : . nday n’a encore aucune trace de correctif ; cela ne veut pas dire qu’il n’en existe pas. Cette vulnérabilité ne figure dans aucune des quatre sources de PoC. Aucune inscription au catalogue KEV de la CISA à ce jour.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

local
AV:L in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA ABB
no authentication required
PR:N in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA ABB
no user interaction
UI:N in CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from the CNA ABB
ICS / OT
affected products in the CVE record: ABB · Merging Unit- SMU615, ABB · Relion protection relays - 611 series, ABB · Relion protection relays - 615 series CN 4.0 FP1, ABB · Relion protection relays - 615 series IEC 4.0 FP1, ABB · Relion protection relays - 615 series IEC 5.0, ABB · Relion protection relays - 615 series IEC 5.0 FP1, ABB · Relion protection relays - 620 series IEC/CN 2.0, ABB · Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB · Relion protection relays - RER615, ABB · Relion protection relays - REX640 PCL1 and 3 moreCPE names NVD's analysts give as vulnerable: o:abb:evd4_firmware, o:abb:rec615_firmware, o:abb:red615_iec_firmware, o:abb:ref615_ansi_firmware, o:abb:ref615_iec_firmware, o:abb:ref615r_firmware, o:abb:relion_611_firmware, o:abb:relion_615_ansi_firmware, o:abb:relion_615_cn_firmware, o:abb:relion_615_iec_firmware and 9 morenday's type rule vendor:abb
étape actuelle
DIS
divulgation
CVSS
6.2 MEDIUM v3.1

Cycle de vie

Axe en UTC ; point = minute exacte, barre large = date seule, creux = inconnue ou déduite.
date inconnue
DISdivulguée
2023-02-28T04:21Z
PATcorrectif
aucune donnée
ANAanalyse
aucune donnée
POCPoC
aucune donnée
ITWexploitée
aucune donnée
KEVKEV
aucune donnée

Résumé

Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:L
Local: needs a local or SSH session, or a user tricked into acting on the machine
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

CVSS 3.1 vector from the CVE record, scored by the CNA ABB.

Journal des événements

+DISdivulgation

Fiche CVE publiée par ABB. CVSS 6.2, gravité moyenne.

source cvelist · importé en masse par nday le · brut
{
  "id": 236507,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2021-22283",
  "occurred_at": "2023-02-28T04:21:41.776Z",
  "observed_at": "2026-11-13T05:37:18.83833Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
      "version": "3.1",
      "base_score": 6.2,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2025-03-07T18:11:58.860932Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2023-02-28T04:21:41.776Z",
    "assigner_short_name": "ABB"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Échanges entre chercheurs

0 chercheur en a parlé ces 7 derniers jours

Publications sur X de chercheurs suivis par nday citant cette CVE, telles que publiées. nday ne les vérifie pas.

nday n’a encore recueilli aucune publication sur X d’un chercheur de sa liste citant cette CVE.

Discussion

0 comments

No comments yet.