nday
CVE-2021-20595

Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air…Titre composé par nday ; la fiche CVE n’en comporte pas.

Divulgation : . nday n’a encore aucune trace de correctif ; cela ne veut pas dire qu’il n’en existe pas. Cette vulnérabilité ne figure dans aucune des quatre sources de PoC. Aucune inscription au catalogue KEV de la CISA à ce jour.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

XXE
CWE-611, stated by NVD's analysts
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H (CVSS 3.1) from NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H (CVSS 3.1) from NVD's analysts
étape actuelle
DIS
divulgation
CVSS
pas encore de score

Cycle de vie

Axe en UTC ; point = minute exacte, barre large = date seule, creux = inconnue ou déduite.
date inconnue
DISdivulguée
2021-07-13T10:54Z
PATcorrectif
aucune donnée
ANAanalyse
aucune donnée
POCPoC
aucune donnée
ITWexploitée
aucune donnée
KEVKEV
aucune donnée

Résumé

Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets.

Original text of the CVE record (cvelist), shown as published.

Journal des événements

+DISdivulgation

Fiche CVE publiée par Mitsubishi.

source cvelist · importé en masse par nday le · brut
{
  "id": 235123,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2021-20595",
  "occurred_at": "2021-07-13T10:54:01Z",
  "observed_at": "2026-11-13T05:37:18.83833Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2021-07-13T10:54:01.000Z",
    "assigner_short_name": "Mitsubishi"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Échanges entre chercheurs

0 chercheur en a parlé ces 7 derniers jours

Publications sur X de chercheurs suivis par nday citant cette CVE, telles que publiées. nday ne les vérifie pas.

nday n’a encore recueilli aucune publication sur X d’un chercheur de sa liste citant cette CVE.

Discussion

0 comments

No comments yet.