nday
CVE-2019-25720

Dräger SC Monitoring Devices DoS via Malformed Network Packet

Dräger / SC 6002XL, SC6802XL, SC 7000, SC8000, SC90000 XL

Divulgation : . nday n’a encore aucune trace de correctif ; cela ne veut pas dire qu’il n’en existe pas. Cette vulnérabilité ne figure dans aucune des quatre sources de PoC. Aucune inscription au catalogue KEV de la CISA à ce jour.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

adjacent network
AV:A in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA VulnCheck
no authentication required
PR:N in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA VulnCheck
no user interaction
UI:N in CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA VulnCheck
étape actuelle
DIS
divulgation
CVSS
7.1 HIGH v4.0

Cycle de vie

Axe en UTC ; point = minute exacte, barre large = date seule, creux = inconnue ou déduite.
date inconnue
DISdivulguée
06-03T16:56Z
PATcorrectif
aucune donnée
ANAanalyse
aucune donnée
POCPoC
aucune donnée
ITWexploitée
aucune donnée
KEVKEV
aucune donnée

Résumé

Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:A
Adjacent: only from a nearby network, such as the same LAN segment or Bluetooth range
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA VulnCheck.

Journal des événements

+DISdivulgation

Fiche CVE publiée par VulnCheck. CVSS 7.1, gravité élevée.

source cvelist · importé en masse par nday le · brut
{
  "id": 210524,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2019-25720",
  "occurred_at": "2026-06-03T16:56:29.683Z",
  "observed_at": "2026-11-13T05:37:01.102615Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 7.1,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2026-06-03T17:44:08.218138Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2026-06-03T16:56:29.683Z",
    "assigner_short_name": "VulnCheck"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Échanges entre chercheurs

0 chercheur en a parlé ces 7 derniers jours

Publications sur X de chercheurs suivis par nday citant cette CVE, telles que publiées. nday ne les vérifie pas.

nday n’a encore recueilli aucune publication sur X d’un chercheur de sa liste citant cette CVE.

Discussion

0 comments

No comments yet.