bpf: Support for hardening against JIT spraying

Linux / Linux

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

local
AV:L in CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H (CVSS 3.1) from NVD's analysts
Linux kernel
affected products in the CVE record: Linux · LinuxCPE names NVD's analysts give as vulnerable: o:linux:linux_kernel
operating system
affected products in the CVE record: Linux · LinuxCPE names NVD's analysts give as vulnerable: o:linux:linux_kernelthe product type of Linux kernel in nday's product registry
etapa
DIS
divulgación
cvss
sin puntuación aún

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
07-25T08:52Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

In the Linux kernel, the following vulnerability has been resolved:

bpf: Support for hardening against JIT spraying

The BPF JIT allocator packs many small programs into larger executable allocations and reuses space within those allocations as programs are loaded and freed. When fresh code is written into space that a previous program occupied, an indirect jump into the new program can reuse a branch prediction left behind by the old one.

Flush the indirect branch predictors before reusing JIT memory so that indirect jumps into a newly written program don't reuse predictions from an old program that occupied the same space.

Introduce bpf_arch_pred_flush_enabled static key and bpf_arch_pred_flush static call for flushing the branch predictors on JIT memory reuse. Architectures that need a flush, can update it to a predictor flush function. By default, its a NOP and does not emit any CALL.

Allocations larger than a pack are not covered by this flush. That is safe because cBPF programs (the unprivileged attack surface) are bounded well below a pack size. Issue a warning if this assumption is ever violated while the flush is active.

Original text of the CVE record (cvelist), shown as published.

Registro de eventos

+DISdivulgación

Linux publicó el registro CVE.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 12758,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2026-64508",
  "occurred_at": "2026-07-25T08:52:01.732Z",
  "observed_at": "2026-11-12T14:10:31.286634Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "ssvc": {
      "timestamp": "2026-11-06T16:40:46.106500Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2026-07-25T08:52:01.732Z",
    "assigner_short_name": "Linux"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.