nday
CVE-2026-11414

Unauthenticated File Exfiltration in Altium Enterprise Server Vault Service via Hard-coded Cryptographic Key and Path Traversal

Altium / Altium Enterprise Server

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

path traversal
CWE-22, stated by the CNA Altium y NVD, republishing 4760f414-e1ae-4ff1-bdad-c7a9c3538b79
hard-coded credentials
CWE-798, stated by the CNA Altium y NVD, republishing 4760f414-e1ae-4ff1-bdad-c7a9c3538b79
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA Altium
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA Altium
no authentication required
PR:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA Altium
no user interaction
UI:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H (CVSS 4.0) from the CNA Altium
etapa
DIS
divulgación
cvss
10.0 CRITICAL v4.0

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
06-05T19:01Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A hard-coded cryptographic key is used by Altium Enterprise Server to sign file download URLs in the Vault service. Because the key is identical across all installations, an unauthenticated network attacker who can reach the server can forge valid download signatures and retrieve files from the Vault storage area without any authentication, session, or credentials.

A separate path traversal vulnerability in the same download endpoint allows the configured storage root to be escaped, enabling reads of arbitrary files on the server filesystem. Combined, these issues allow an unauthenticated attacker to obtain sensitive server configuration and key material, which can lead to full server compromise. The vulnerability can be chained with CVE-2026-9152 to enumerate and bulk-download stored content. Altium 365 cloud deployments are not impacted in practice, as file storage uses object storage rather than the local filesystem.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

CVSS 4.0 vector from the CVE record, scored by the CNA Altium.

Registro de eventos

+DISdivulgación

Altium publicó el registro CVE. CVSS 10, severidad crítica.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 402510,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2026-11414",
  "occurred_at": "2026-06-05T19:01:12.061Z",
  "observed_at": "2026-11-13T05:39:28.449279Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
      "version": "4.0",
      "base_score": 10,
      "base_severity": "CRITICAL"
    },
    "ssvc": {
      "timestamp": "2026-06-09T14:20:55.464260Z",
      "automatable": "yes",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2026-06-05T19:01:12.061Z",
    "assigner_short_name": "Altium"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.