nday
CVE-2024-20263

Cisco Small Business Smart and Managed Switches: broken access controlTítulo compuesto por nday; el registro CVE no tiene título.

Cisco / Cisco Small Business Smart and Managed Switches

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

broken access control
CWE-284, stated by the CNA cisco y NVD, republishing [email protected]
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N (CVSS 3.1) from the CNA cisco
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N (CVSS 3.1) from the CNA cisco
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N (CVSS 3.1) from the CNA cisco
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N (CVSS 3.1) from the CNA cisco
etapa
DIS
divulgación
cvss
5.8 MEDIUM v3.1

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2024-01-26T17:27Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A vulnerability with the access control list (ACL) management within a stacked switch configuration of Cisco Business 250 Series Smart Switches and Business 350 Series Managed Switches could allow an unauthenticated, remote attacker to bypass protection offered by a configured ACL on an affected device. This vulnerability is due to incorrect processing of ACLs on a stacked configuration when either the primary or backup switches experience a full stack reload or power cycle. An attacker could exploit this vulnerability by sending crafted traffic through an affected device. A successful exploit could allow the attacker to bypass configured ACLs, causing traffic to be dropped or forwarded in an unexpected manner. The attacker does not have control over the conditions that result in the device being in the vulnerable state. Note: In the vulnerable state, the ACL would be correctly applied on the primary devices but could be incorrectly applied to the backup devices.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N

CVSS 3.1 vector from the CVE record, scored by the CNA cisco.

Registro de eventos

+DISdivulgación

cisco publicó el registro CVE. CVSS 5.8, severidad media.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 323566,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2024-20263",
  "occurred_at": "2024-01-26T17:27:08.928Z",
  "observed_at": "2026-11-13T05:38:25.834778Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
      "version": "3.1",
      "base_score": 5.8,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2024-01-31T16:31:15.728944Z",
      "automatable": "yes",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2024-01-26T17:27:08.928Z",
    "assigner_short_name": "cisco"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.