nday
CVE-2023-52891

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC…Título compuesto por nday; el registro CVE no tiene título.

Siemens / SIMATIC Energy Manager Basic, SIMATIC Energy Manager PRO, SIMATIC IPC DiagBase, SIMATIC IPC DiagMonitor, SIMIT V10, SIMIT V11

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L (CVSS 3.1) from the CNA siemens
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L (CVSS 3.1) from the CNA siemens
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L (CVSS 3.1) from the CNA siemens
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L (CVSS 3.1) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC Energy Manager Basic, Siemens · SIMATIC Energy Manager PRO, Siemens · SIMATIC IPC DiagBase, Siemens · SIMATIC IPC DiagMonitor
ICS / OT
affected products in the CVE record: Siemens · SIMATIC Energy Manager Basic, Siemens · SIMATIC Energy Manager PRO, Siemens · SIMATIC IPC DiagBase, Siemens · SIMATIC IPC DiagMonitorthe product type of Siemens SIMATIC in nday's product registry
etapa
DIS
divulgación
cvss
5.3 MEDIUM v3.1

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2024-07-09T12:04Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

CVSS 3.1 vector from the CVE record, scored by the CNA siemens.

Registro de eventos

+DISdivulgación

siemens publicó el registro CVE. CVSS 5.3, severidad media.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 309171,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2023-52891",
  "occurred_at": "2024-07-09T12:04:42.619Z",
  "observed_at": "2026-11-13T05:38:14.046808Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
      "version": "3.1",
      "base_score": 5.3,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2024-07-09T13:26:14.481281Z",
      "automatable": "yes",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2024-07-09T12:04:42.619Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.