nday
CVE-2023-50821

Siemens SIMATIC: buffer overflow / out-of-bounds writeTítulo compuesto por nday; el registro CVE no tiene título.

Siemens / SIMATIC PCS 7 V9.1, SIMATIC WinCC Runtime Professional V17, SIMATIC WinCC Runtime Professional V18, SIMATIC WinCC Runtime Professional V19, SIMATIC WinCC V7.5, SIMATIC WinCC V8.0

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

buffer overflow / out-of-bounds write
CWE-120, stated by the CNA siemens y NVD, republishing [email protected]
local
AV:L in CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
no authentication required
PR:N in CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
no user interaction
UI:N in CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA siemens
Siemens SIMATIC
affected products in the CVE record: Siemens · SIMATIC PCS 7 V9.1, Siemens · SIMATIC WinCC Runtime Professional V17, Siemens · SIMATIC WinCC Runtime Professional V18, Siemens · SIMATIC WinCC Runtime Professional V19, Siemens · SIMATIC WinCC V7.5, Siemens · SIMATIC WinCC V8.0
ICS / OT
affected products in the CVE record: Siemens · SIMATIC PCS 7 V9.1, Siemens · SIMATIC WinCC Runtime Professional V17, Siemens · SIMATIC WinCC Runtime Professional V18, Siemens · SIMATIC WinCC Runtime Professional V19, Siemens · SIMATIC WinCC V7.5, Siemens · SIMATIC WinCC V8.0the product type of Siemens SIMATIC in nday's product registry
etapa
DIS
divulgación
cvss
6.9 MEDIUM v4.0

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2024-04-09T08:34Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:L
Local: needs a local or SSH session, or a user tricked into acting on the machine
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA siemens.

Registro de eventos

+DISdivulgación

siemens publicó el registro CVE. CVSS 6.9, severidad media.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 307641,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2023-50821",
  "occurred_at": "2024-04-09T08:34:35.452Z",
  "observed_at": "2026-11-13T05:38:12.722845Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 6.9,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2024-08-12T13:48:36.486525Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2024-04-09T08:34:35.452Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.