nday
CVE-2023-45321

Bosch Rexroth ctrlX HMI Web Panel - WR21 (WR2107): cryptographic failureTítulo compuesto por nday; el registro CVE no tiene título.

Bosch Rexroth AG / ctrlX HMI Web Panel - WR21 (WR2107), ctrlX HMI Web Panel - WR21 (WR2110), ctrlX HMI Web Panel - WR21 (WR2115)

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

cryptographic failure
CWE-319, stated by the CNA bosch, NVD's analysts y NVD, republishing [email protected]
adjacent network
AV:A in CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L (CVSS 3.1) from the CNA bosch
no authentication required
PR:N in CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L (CVSS 3.1) from the CNA bosch
no user interaction
UI:N in CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L (CVSS 3.1) from the CNA bosch
etapa
DIS
divulgación
cvss
8.3 HIGH v3.1

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2023-10-25T14:16Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:A
Adjacent: only from a nearby network, such as the same LAN segment or Bluetooth range
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L

CVSS 3.1 vector from the CVE record, scored by the CNA bosch.

Registro de eventos

+DISdivulgación

bosch publicó el registro CVE. CVSS 8.3, severidad alta.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 304143,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2023-45321",
  "occurred_at": "2023-10-25T14:16:41.097Z",
  "observed_at": "2026-11-13T05:38:09.805315Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
      "version": "3.1",
      "base_score": 8.3,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2024-09-11T16:00:25.907168Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2023-10-25T14:16:41.097Z",
    "assigner_short_name": "bosch"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.