nday
CVE-2023-33920

Siemens CP-8031 MASTER MODULE: hard-coded credentialsTítulo compuesto por nday; el registro CVE no tiene título.

Siemens / CP-8031 MASTER MODULE, CP-8050 MASTER MODULE

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

hard-coded credentials
CWE-798, stated by the CNA siemens, NVD's analysts y NVD, republishing [email protected]
physical
AV:P in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no authentication required
PR:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
no user interaction
UI:N in CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C (CVSS 3.1) from the CNA siemens
etapa
DIS
divulgación
cvss
6.8 MEDIUM v3.1

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2023-06-13T08:17Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain the hash of the root password in a hard-coded form, which could be exploited for UART console login to the device. An attacker with direct physical access could exploit this vulnerability.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:P
Physical: needs physical access to the device
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

CVSS 3.1 vector from the CVE record, scored by the CNA siemens.

Registro de eventos

+DISdivulgación

siemens publicó el registro CVE. CVSS 6.8, severidad media.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 296700,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2023-33920",
  "occurred_at": "2023-06-13T08:17:19.819Z",
  "observed_at": "2026-11-13T05:38:05.30163Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
      "version": "3.1",
      "base_score": 6.8,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2025-01-03T01:34:38.544377Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "total"
    },
    "state": "PUBLISHED",
    "date_published": "2023-06-13T08:17:19.819Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.