Medtronic MiniMed 600 Series Pump System Communication Issue

Medtronic / Minimed 600 Series Insulin Pump

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

adjacent network
AV:A in CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from the CNA Medtronic
no user interaction
UI:N in CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N (CVSS 3.1) from the CNA Medtronic
etapa
DIS
divulgación
cvss
4.8 MEDIUM v3.1

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2022-11-17T20:47Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:A
Adjacent: only from a nearby network, such as the same LAN segment or Bluetooth range
Attack complexity AC:H
High: success depends on conditions outside the attacker's control, such as gathering details of the target or winning a race
Privileges required PR:L
Low: ordinary user privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N

CVSS 3.1 vector from the CVE record, scored by the CNA Medtronic.

Registro de eventos

+DISdivulgación

Medtronic publicó el registro CVE. CVSS 4.8, severidad media.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 267669,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-32537",
  "occurred_at": "2022-11-17T20:47:05.258Z",
  "observed_at": "2026-11-13T05:37:42.261111Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N",
      "version": "3.1",
      "base_score": 4.8,
      "base_severity": "MEDIUM"
    },
    "ssvc": {
      "timestamp": "2025-04-29T14:44:04.441292Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2022-11-17T20:47:05.258Z",
    "assigner_short_name": "Medtronic"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.