nday
CVE-2022-25779

Insufficient scope checks allows adding unrelated audit log entries

Secomea / GateManager

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

resource exhaustion
CWE-400, stated by NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N (CVSS 3.1) from the CNA Secomea
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N (CVSS 3.1) from the CNA Secomea
etapa
DIS
divulgación
cvss
4.3 MEDIUM v3.1

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2022-05-04T13:51Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no special conditions; the attacker can expect repeatable success
Privileges required PR:L
Low: ordinary user privileges
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N

CVSS 3.1 vector from the CVE record, scored by the CNA Secomea.

Registro de eventos

+DISdivulgación

Secomea publicó el registro CVE. CVSS 4.3, severidad media.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 262901,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-25779",
  "occurred_at": "2022-05-04T13:51:08Z",
  "observed_at": "2026-11-13T05:37:39.263299Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
      "version": "3.1",
      "base_score": 4.3,
      "base_severity": "MEDIUM"
    },
    "state": "PUBLISHED",
    "date_published": "2022-05-04T13:51:08.000Z",
    "assigner_short_name": "Secomea"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.